Do you have a sample program for 485 communication?
We do not offer a sample program for the programmable controller. Refer to the Instruction Manual and create the program by yourself. More Details >>
- No:21522
- Release Date:2018/08/22 16:28
-
If the MC on the input side is shut off using the fault output of the FR-E500, the inverter's fault records are left in the faults history. More Details >>
- No:22096
- Release Date:2018/08/22 16:30
-
When consuming the regenerative power with the brake resistor, the brake transistor is triggered at a certain voltage to make the brake resistor use the rege... More Details >>
- No:22074
- Release Date:2018/08/22 16:30
-
The major differences are:- Capacity range- Availability of regenerative brake resistor- Operation of the operation panel- Number of I/O terminals More Details >>
- No:22056
- Release Date:2018/08/22 16:30
-
Notes when inverter capacity is larger than motor capacity
When using one-rank-higher inverter, as you mention, you need to care about the setting of the electronic thermal O/L relay.Setting the electronic thermal O/... More Details >>
- No:22040
- Release Date:2018/08/22 16:30
-
Connection with personal computer
Connection method for the A500 and E500 is shown in the figure below. The figure is given in an Excel file. Figure 1 More Details >>
- No:21536
- Release Date:2018/08/22 16:28
-
Countermeasures when input power supply is turned off upon equipment fault
1. When the inverter power supply is turned OFF, the inverter is disconnected from the CC-Link network. However, since the CC-Link master station has the aut... More Details >>
- No:21390
- Release Date:2018/08/22 16:27
-
You can use the Hioki Memory HiCorder and clamp-on AC/DC high tester.You can observe the inverter's frequency in one of the following two methods:1. Attach t... More Details >>
- No:22082
- Release Date:2018/08/22 16:30
-
Operation command terminal switching
It rotates in the forward direction while STF is ON.And then, when STR is turned ON and STF is turned OFF, the inverter decelerates down to 0 Hz within the s... More Details >>
- No:22070
- Release Date:2018/08/22 16:30
-
The inverter uses PWM control to change the output voltage and frequency to vary the motor speed. PWM stands for Pulse Width Modulation. Voltage is chopped i... More Details >>
- No:21549
- Release Date:2018/08/22 16:28