  • Communication operation with FR-E500

    We have no sample program for RS485 communication. Since the communication method of the FR-SW0-SETUP uses a different protocol from 485 communication and st... More Details >>

    • No:21451
    • Release Date:2018/08/22 16:27
  • Relationship between frequency and output torque

    The output torque characteristics of the FREQROL-E500 series are shown in the figure below. Figure 1 More Details >>

    • No:22024
    • Release Date:2018/08/22 16:30
  • Endurance

    The estimated lives of the parts of the FREQROL-E500 are as follows: Cooling fan at surrounding air temperature of 35 deg C???30,000 hrsPower supply smoothin... More Details >>

    • No:22071
    • Release Date:2018/08/22 16:30
  • CC-Link

    Already released.Unlike the E520, you need to purchase the optional card FR-E5NC. More Details >>

    • No:22050
    • Release Date:2018/08/22 16:30
  • Clutch connection of load

    Since a large load is applied to the motor when the electromagnetic clutch turns on, overcurrent may occur if the load is heavy. To ensure that the rated cur... More Details >>

    • No:21955
    • Release Date:2018/08/22 16:30
  • Operation panel

    Be sure to use the FR-E5P to mount the operation panel.This is because the board is bare on the back of the operation panel and a dedicated connector is requ... More Details >>

    • No:22030
    • Release Date:2018/08/22 16:30
  • Parameter unit display

    Setting Pr.37 to the machine speed at 60 Hz switches the frequency monitor to the rotations per minute monitor.Note that the speed setting must be input in a... More Details >>

    • No:22072
    • Release Date:2018/08/22 16:30
  • Frequency display deviation

    If you are using an external VR, influence by noise is probable.Setting Pr.74 (Input filter time constant) to a higher value stabilizes the frequency command... More Details >>

    • No:22061
    • Release Date:2018/08/22 16:30
  • Direct driven start by power supply

    The warning "Do not use a magnetic contactor on the inverter input for frequent starting/stopping of the inverter." is indicated in the precautions at the be... More Details >>

    • No:21458
    • Release Date:2018/08/22 16:27
  • Inverter input power supply

    Square wave input is not recommended since it can cause failures (for example, damage the diode bridge). More Details >>

    • No:22106
    • Release Date:2018/08/22 16:31