  • Inverter input power supply

    Square wave input is not recommended since it can cause failures (for example, damage the diode bridge). More Details >>

    • No:22106
    • Release Date:2018/08/22 16:31
  • Operation panel extension cable

    Yes, you can use the 10BASE-T cable (straight) with the E500. More Details >>

    • No:22085
    • Release Date:2018/08/22 16:30
  • Inverter outline dimension CAD data

    The outline dimension diagram is found on the member's page of Mitsubishi Electric FA Global Website.Contact our sales personnel for details on the programma... More Details >>

    • No:22053
    • Release Date:2018/08/22 16:30
  • Analog output

    The FM output is 0 to 8 VDC pulse. More Details >>

    • No:22039
    • Release Date:2018/08/22 16:30
  • Alarm output signal when using CC-Link

    The RX7 output signal is the same as the signals for NO, NC, and transfer contact output.You can change the contents of this output signal using Pr.192.Pr.19... More Details >>

    • No:22008
    • Release Date:2018/08/22 16:30
  • Parameters not covered in manual are displayed

    Pr.168 indicates the inverter software version.Pr.169 indicates the inverter software subversion history. These two parameters are only used by the manufactu... More Details >>

    • No:21532
    • Release Date:2018/08/22 16:28
  • Operation frequency

    I cannot answer clearly because the load is unknown. The operation cycle of operating for 10 seconds and stopping for 10 seconds is OK, but it is questionabl... More Details >>

    • No:21474
    • Release Date:2018/08/22 16:27
  • Current monitor display

    The current monitor displays the average value of the three-phase current. The three-phase voltage is not incorporated for the voltage monitor. The output vo... More Details >>

    • No:21376
    • Release Date:2018/08/22 16:27
  • Parameter unit display

    Setting Pr.37 to the machine speed at 60 Hz switches the frequency monitor to the rotations per minute monitor.Note that the speed setting must be input in a... More Details >>

    • No:22072
    • Release Date:2018/08/22 16:30
  • Endurance

    The estimated lives of the parts of the FREQROL-E500 are as follows: Cooling fan at surrounding air temperature of 35 deg C???30,000 hrsPower supply smoothin... More Details >>

    • No:22071
    • Release Date:2018/08/22 16:30