  • Motor wiring length

    Up to 50 m. Be sure to connect the encoder cables in parallel and use the thicker cable gauge. You can extend this distance up to 100 m by using the long dis... More Details >>

    • No:21641
    • Release Date:2018/08/22 16:28
  • Torque control accuracy

    Since the torque control accuracy is influenced by change of motor temperature:- Standard product???±5% (at 75 deg C) ±0.5%/deg C of rated torque- Combinatio... More Details >>

    • No:21645
    • Release Date:2018/08/22 16:28
  • Manufacturing of 6P dedicated motor

    We cannot manufacture a 6P by SF-VR dedicated motor. Use a motor with 6P encoder. More Details >>

    • No:21646
    • Release Date:2018/08/22 16:28
  • Geared motor

    We do not offer a geared motor. More Details >>

    • No:21647
    • Release Date:2018/08/22 16:28
  • Model configuration

    12 models of FREQROL-V200 vector inverters each for the 200 V and 400 V classes from 1.5K to 45K. 9 models of SF-VR vector control dedicated motors each for ... More Details >>

    • No:21657
    • Release Date:2018/08/22 16:28
  • Speed control range

    1:1500 when using a vector control dedicated motor. Continuous 100% torque operation and short-time 150% torque operation are possible even at 1 rpm. Continu... More Details >>

    • No:21662
    • Release Date:2018/08/22 16:28
  • Unwinding using vector inverter

    1. Torque control automatically adjust the speed so that the instructed torque value is maintained. This means that the speed is not controlled. (However, yo... More Details >>

    • No:21420
    • Release Date:2018/08/22 16:27
  • Motor characteristics at low input voltage

    Since the dedicated motor is designed with the rated voltage of approximately 320 V, it can produce sufficient torque for the input voltage of 380 V. Therefo... More Details >>

    • No:21434
    • Release Date:2018/08/22 16:27
  • Rotations per minute vary

    It is considered that conditions including the power supply and noise change whether the parameter unit is connected or disconnected, influencing the analog ... More Details >>

    • No:21454
    • Release Date:2018/08/22 16:27
  • Static torque

    When a vector inverter is used for position control, the servo lock works when it is stopped. When the start signal (STF or STR) is turned ON, the servo lock... More Details >>

    • No:21502
    • Release Date:2018/08/22 16:28