  • Meaning of OL display

    "OL" stands for "overload". Whenever current of 150% or more of the inverter rated current flows, "OL" is ON. If you continue operation with "OL" is displaye... More Details >>

    • No:21449
    • Release Date:2018/08/22 16:27
  • Meaning of OL display (2)

    Yes. "OL" is displayed under speed control whenever the torque limit is reached without regard to the rated torque. More Details >>

    • No:21448
    • Release Date:2018/08/22 16:27
  • Operation under torque limit in the speed control mode

    Under a 50% torque limit, if the commanded speed (50 Hz in your example) cannot be achieved without torque exceeding 50%, since the torque does not exceed th... More Details >>

    • No:21483
    • Release Date:2018/08/22 16:27
  • Automatic restart after instantaneous power failure

    1. Yes. The inverter cannot restart if STF and STR are turned OFF.However, on the next startup, the inverter detects coasting and restarts.2. When automatic ... More Details >>

    • No:21942
    • Release Date:2018/08/22 16:30
  • Automatic restart after instantaneous power failure

    The inverter has the automatic restart after instantaneous power failure function. By setting Pr.61 to other than "9999", the encoder detects the speed of th... More Details >>

    • No:21642
    • Release Date:2018/08/22 16:28
  • Feature

    By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>

    • No:21664
    • Release Date:2018/08/22 16:28
  • Surge voltage of 400 V inverter

    No. Although the carrier frequency increases or decreases the switching count, the switching speed is the OFF-to-ON speed of the IGBT element of the inverter... More Details >>

    • No:21401
    • Release Date:2018/08/22 16:27
  • Position control

    The servo motor provides the highest precision and response.With the vector inverter, position control using pulse train input ensures position control at pr... More Details >>

    • No:22036
    • Release Date:2018/08/22 16:30
  • Structures of dedicated motor

    We offer the following: <<Dedicated motor model variation>>- With standard legs (SF-VR__)5.5 kW, 7.5 kW, 11 kW, 15 kW, 18.5 kW, 22 kW, 30 kW, 37 ... More Details >>

    • No:21649
    • Release Date:2018/08/22 16:28
  • Speed fluctuation ratio

    1. Speed fluctuation ratio when using the FR-V200 + dedicated motor (with an encoder) The vector inverter FR-V200 detects speed by the encoder and speed fluc... More Details >>