1:1500 when using a vector control dedicated motor. Continuous 100% torque operation and short-time 150% torque operation are possible even at 1 rpm. Continu... More Details >>
- No:21662
- Release Date:2018/08/22 16:28
-
Inverter current characteristics
In general, relationship between T (torque), K (constant), V (voltage), I (current), and F (frequency) is expressed as "T = K × (V/F) × I". Since (V/F) is co... More Details >>
- No:21505
- Release Date:2018/08/22 16:28
-
Use of general-purpose servo motor
You can operate it by adjusting the motor constant by the auto tuning function. (Note that the same characteristics as operated by the servo amplifier MR-VA ... More Details >>
- No:21652
- Release Date:2018/08/22 16:28
-
Automatic restart after instantaneous power failure
The inverter has the automatic restart after instantaneous power failure function. By setting Pr.61 to other than "9999", the encoder detects the speed of th... More Details >>
- No:21642
- Release Date:2018/08/22 16:28
-
It is considered that conditions including the power supply and noise change whether the parameter unit is connected or disconnected, influencing the analog ... More Details >>
- No:21454
- Release Date:2018/08/22 16:27
-
It can be output by attaching the plug-in option FR-VPA, FR-VPB, or FR-VPC. Note that the output format depends on the option type. FR-VPA: Open collector ou... More Details >>
- No:21643
- Release Date:2018/08/22 16:28
-
Yes. "OL" is displayed under speed control whenever the torque limit is reached without regard to the rated torque. More Details >>
- No:21448
- Release Date:2018/08/22 16:27
-
I use the dedicated motor SF-VR with the same capacity as the inverter. 1. Load fluctuationSpeed fluctuation ratio with the load fluctuation 0 to 100% is:Wit... More Details >>
- No:21490
- Release Date:2018/08/22 16:27
-
Encoder cable length restriction
If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>
- No:21932
- Release Date:2018/08/22 16:30
-
12 models of FREQROL-V200 vector inverters each for the 200 V and 400 V classes from 1.5K to 45K. 9 models of SF-VR vector control dedicated motors each for ... More Details >>
- No:21657
- Release Date:2018/08/22 16:28