Automatic restart after instantaneous power failure
1. Yes. The inverter cannot restart if STF and STR are turned OFF.However, on the next startup, the inverter detects coasting and restarts.2. When automatic ... More Details >>
- No:21942
- Release Date:2018/08/22 16:30
-
The following amount of heat is generated under the 100% load. (The same amount for both the 200 V and 400 V classes. The amount of heat generated by the bui... More Details >>
- No:21568
- Release Date:2018/08/22 16:28
-
Difference from general-purpose inverter
While the inverter uses open-loop (V/F) control, it uses semi-closed loop vector control (constant current control). This enables output of stable torque esp... More Details >>
- No:21659
- Release Date:2018/08/22 16:28
-
By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>
- No:21664
- Release Date:2018/08/22 16:28
-
When a vector inverter is used for position control, the servo lock works when it is stopped. When the start signal (STF or STR) is turned ON, the servo lock... More Details >>
- No:21502
- Release Date:2018/08/22 16:28
-
You cannot reuse the plug-in option for the FREQROL-A200 and A100 series. You must use one of the following three plug-in options dedicated to the FREQROL-V2... More Details >>
- No:21656
- Release Date:2018/08/22 16:28
-
Motor characteristics at low input voltage
Since the dedicated motor is designed with the rated voltage of approximately 320 V, it can produce sufficient torque for the input voltage of 380 V. Therefo... More Details >>
- No:21434
- Release Date:2018/08/22 16:27
-
Vector control performs high-accuracy calculation using the motor constant. Therefore, to perform vector control operation, the inverter must recognize the m... More Details >>
- No:21663
- Release Date:2018/08/22 16:28
-
Operation under torque limit in the speed control mode
Under a 50% torque limit, if the commanded speed (50 Hz in your example) cannot be achieved without torque exceeding 50%, since the torque does not exceed th... More Details >>
- No:21483
- Release Date:2018/08/22 16:27
-
In addition to speed control, you can also select torque control as well as you can perform position control using an option. The speed control range is as l... More Details >>
- No:21655
- Release Date:2018/08/22 16:28