Connect the external potentiometer to the terminals 10, 2, and 5 of the first inverter (be sure to connect the variable terminal to the terminal 2). Connect ... More Details >>
- No:21462
- Release Date:2018/08/22 16:27
-
What happens if reset occurs during operation?
This is because when the inverter restarts while the motor is coasting, an overcurrent trip can occur during the restart process. However, the recent types o... More Details >>
- No:21477
- Release Date:2018/08/22 16:27
-
Yes. "OL" is displayed under speed control whenever the torque limit is reached without regard to the rated torque. More Details >>
- No:21448
- Release Date:2018/08/22 16:27
-
When the wire between the 400 V inverter and motor is long (20 m or longer), surge voltage occurs momentarily. This voltage is as two or more times as the DC... More Details >>
- No:21404
- Release Date:2018/08/22 16:27
-
Angular velocity change control
The inverter itself does not have a function to detect the rotation angle and change the velocity accordingly. Therefore, to implement required control, it i... More Details >>
- No:22086
- Release Date:2018/08/22 16:30
-
The specifications of the FR-V200E series do not allow for choosing from "Reset input always enabled" and "Reset input enabled only when the protective funct... More Details >>
- No:22031
- Release Date:2018/08/22 16:30
-
Use of general-purpose servo motor
You can operate it by adjusting the motor constant by the auto tuning function. (Note that the same characteristics as operated by the servo amplifier MR-VA ... More Details >>
- No:21652
- Release Date:2018/08/22 16:28
-
Can I change the carrier frequency?
You can change it by changing the setting of Pr.72 (PWM frequency selection). Setting range of Pr.72: 0, 1, 2, 3, 4, 5, 6 (Initial setting is "6".) (The smal... More Details >>
- No:21640
- Release Date:2018/08/22 16:28
-
I use the dedicated motor SF-VR with the same capacity as the inverter. 1. Load fluctuationSpeed fluctuation ratio with the load fluctuation 0 to 100% is:Wit... More Details >>
- No:21490
- Release Date:2018/08/22 16:27
-
Encoder cable length restriction
If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>
- No:21932
- Release Date:2018/08/22 16:30