Since the torque control accuracy is influenced by change of motor temperature:- Standard product???±5% (at 75 deg C) ±0.5%/deg C of rated torque- Combinatio... More Details >>
- No:21645
- Release Date:2018/08/22 16:28
-
We offer the following: <<Dedicated motor model variation>>- With standard legs (SF-VR__)5.5 kW, 7.5 kW, 11 kW, 15 kW, 18.5 kW, 22 kW, 30 kW, 37 ... More Details >>
- No:21649
- Release Date:2018/08/22 16:28
-
Encoder cable length restriction
If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>
- No:21932
- Release Date:2018/08/22 16:30
-
Unwinding using vector inverter
1. Torque control automatically adjust the speed so that the instructed torque value is maintained. This means that the speed is not controlled. (However, yo... More Details >>
- No:21420
- Release Date:2018/08/22 16:27
-
We do not offer an explosion-proof type of vector inverter. More Details >>
- No:21644
- Release Date:2018/08/22 16:28
-
Motor characteristics at low input voltage
Since the dedicated motor is designed with the rated voltage of approximately 320 V, it can produce sufficient torque for the input voltage of 380 V. Therefo... More Details >>
- No:21434
- Release Date:2018/08/22 16:27
-
I want to drive other manufacturer's motor with PG
You can drive the motor with the FR-V240E-5.5K. However, the following conditions apply: - You need to perform auto tuning because the motor's circuit consta... More Details >>
- No:21539
- Release Date:2018/08/22 16:28
-
Difference from general-purpose inverter
While the inverter uses open-loop (V/F) control, it uses semi-closed loop vector control (constant current control). This enables output of stable torque esp... More Details >>
- No:21659
- Release Date:2018/08/22 16:28
-
Use Pr.17 (Input terminal assignment) to assign MRS to the terminals DI1, DI2, and DI3. More Details >>
- No:21937
- Release Date:2018/08/22 16:30
-
Yes. "OL" is displayed under speed control whenever the torque limit is reached without regard to the rated torque. More Details >>
- No:21448
- Release Date:2018/08/22 16:27