  • Speed fluctuation ratio

    1. Speed fluctuation ratio when using the FR-V200 + dedicated motor (with an encoder) The vector inverter FR-V200 detects speed by the encoder and speed fluc... More Details >>

    • No:21489
    • Release Date:2018/08/22 16:27
  • Inverter current characteristics

    In general, relationship between T (torque), K (constant), V (voltage), I (current), and F (frequency) is expressed as "T = K × (V/F) × I". Since (V/F) is co... More Details >>

    • No:21505
    • Release Date:2018/08/22 16:28
  • I want to drive other manufacturer's motor with PG

    You can drive the motor with the FR-V240E-5.5K. However, the following conditions apply: - You need to perform auto tuning because the motor's circuit consta... More Details >>

    • No:21539
    • Release Date:2018/08/22 16:28
  • Explosion countermeasure

    We do not offer an explosion-proof type of vector inverter. More Details >>

    • No:21644
    • Release Date:2018/08/22 16:28
  • Structures of dedicated motor

    We offer the following: <<Dedicated motor model variation>>- With standard legs (SF-VR__)5.5 kW, 7.5 kW, 11 kW, 15 kW, 18.5 kW, 22 kW, 30 kW, 37 ... More Details >>

    • No:21649
    • Release Date:2018/08/22 16:28
  • Applicable motors

    In addition to the dedicated motor (SF-VR series), the SF-JR series motor with an encoder can be used. You can also use a standard motor by combining it with... More Details >>

    • No:21653
    • Release Date:2018/08/22 16:28
  • Encoder cable length restriction

    If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>

    • No:21932
    • Release Date:2018/08/22 16:30
  • Surge voltage of 400 V inverter

    No. Although the carrier frequency increases or decreases the switching count, the switching speed is the OFF-to-ON speed of the IGBT element of the inverter... More Details >>

    • No:21401
    • Release Date:2018/08/22 16:27
  • Driving 200 V motor by 400 V inverter

    A 400 V inverter does not operate when 200 V is supplied to it, therefore the motor does not rotate. A 200 V motor can be rotated by a 400 V inverter, howeve... More Details >>

    • No:21446
    • Release Date:2018/08/22 16:27
  • Rotations per minute vary

    It is considered that conditions including the power supply and noise change whether the parameter unit is connected or disconnected, influencing the analog ... More Details >>

    • No:21454
    • Release Date:2018/08/22 16:27