Difference from general-purpose inverter
While the inverter uses open-loop (V/F) control, it uses semi-closed loop vector control (constant current control). This enables output of stable torque esp... More Details >>
- No:21659
- Release Date:2018/08/22 16:28
-
Use Pr.17 (Input terminal assignment) to assign MRS to the terminals DI1, DI2, and DI3. More Details >>
- No:21937
- Release Date:2018/08/22 16:30
-
It is necessary for vector control operation. Use a dedicated motor or a motor with an encoder. If you use another manufacturer's motor, use an encoder capab... More Details >>
- No:21650
- Release Date:2018/08/22 16:28
-
By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>
- No:21664
- Release Date:2018/08/22 16:28
-
The servo motor provides the highest precision and response.With the vector inverter, position control using pulse train input ensures position control at pr... More Details >>
- No:22036
- Release Date:2018/08/22 16:30
-
Automatic restart after instantaneous power failure
The inverter has the automatic restart after instantaneous power failure function. By setting Pr.61 to other than "9999", the encoder detects the speed of th... More Details >>
- No:21642
- Release Date:2018/08/22 16:28
-
Operation under torque limit in the speed control mode
Under a 50% torque limit, if the commanded speed (50 Hz in your example) cannot be achieved without torque exceeding 50%, since the torque does not exceed th... More Details >>
- No:21483
- Release Date:2018/08/22 16:27
-
1. Speed fluctuation ratio when using the FR-V200 + dedicated motor (with an encoder) The vector inverter FR-V200 detects speed by the encoder and speed fluc... More Details >>
- No:21489
- Release Date:2018/08/22 16:27
-
Up to 50 m. Be sure to connect the encoder cables in parallel and use the thicker cable gauge. You can extend this distance up to 100 m by using the long dis... More Details >>
- No:21641
- Release Date:2018/08/22 16:28
-
1:1500 when using a vector control dedicated motor. Continuous 100% torque operation and short-time 150% torque operation are possible even at 1 rpm. Continu... More Details >>
- No:21662
- Release Date:2018/08/22 16:28