FAQ within [ FREQROL-V200 ]

21-30 of Total 52

prev 3 / 6page next
  • Encoder

    It is necessary for vector control operation. Use a dedicated motor or a motor with an encoder. If you use another manufacturer's motor, use an encoder capab... More Details >>

    • No:21650
    • Release Date:2018/08/22 16:28
  • Reusing parameter units

    You cannot reuse the parameter unit (FR-PU01) for the FREQROL-Z series, the parameter unit (FR-PU02) for the FREQROL-A200 and A100 series, and the parameter ... More Details >>

    • No:21654
    • Release Date:2018/08/22 16:28
  • Plug-in options

    You cannot reuse the plug-in option for the FREQROL-A200 and A100 series. You must use one of the following three plug-in options dedicated to the FREQROL-V2... More Details >>

    • No:21656
    • Release Date:2018/08/22 16:28
  • Regeneration unit

    You can reuse the brake units used with the FR-A series, including the FR-RC power regeneration converter, FR-BU, and BU brake unit. You can also use the hig... More Details >>

    • No:21658
    • Release Date:2018/08/22 16:28
  • Auto tuning

    Vector control performs high-accuracy calculation using the motor constant. Therefore, to perform vector control operation, the inverter must recognize the m... More Details >>

    • No:21663
    • Release Date:2018/08/22 16:28
  • Amount of heat generated

    The following amount of heat is generated under the 100% load. (The same amount for both the 200 V and 400 V classes. The amount of heat generated by the bui... More Details >>

    • No:21568
    • Release Date:2018/08/22 16:28
  • Automatic restart after instantaneous power failure

    The inverter has the automatic restart after instantaneous power failure function. By setting Pr.61 to other than "9999", the encoder detects the speed of th... More Details >>

    • No:21642
    • Release Date:2018/08/22 16:28
  • Encoder signal output

    It can be output by attaching the plug-in option FR-VPA, FR-VPB, or FR-VPC. Note that the output format depends on the option type. FR-VPA: Open collector ou... More Details >>

    • No:21643
    • Release Date:2018/08/22 16:28
  • Cycle operation mode, continuous operation mode, torque characteristic selection

    When using a motor with an encoder by performing auto tuning, you need to choose the operation mode or continuous operation mode depending on the application... More Details >>

    • No:21661
    • Release Date:2018/08/22 16:28
  • Position control

    The servo motor provides the highest precision and response.With the vector inverter, position control using pulse train input ensures position control at pr... More Details >>

    • No:22036
    • Release Date:2018/08/22 16:30