Encoder cable length restriction
If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>
- No:21932
- Release Date:2018/08/22 16:30
-
12 models of FREQROL-V200 vector inverters each for the 200 V and 400 V classes from 1.5K to 45K. 9 models of SF-VR vector control dedicated motors each for ... More Details >>
- No:21657
- Release Date:2018/08/22 16:28
-
Can I change the carrier frequency?
You can change it by changing the setting of Pr.72 (PWM frequency selection). Setting range of Pr.72: 0, 1, 2, 3, 4, 5, 6 (Initial setting is "6".) (The smal... More Details >>
- No:21640
- Release Date:2018/08/22 16:28
-
I use the dedicated motor SF-VR with the same capacity as the inverter. 1. Load fluctuationSpeed fluctuation ratio with the load fluctuation 0 to 100% is:Wit... More Details >>
- No:21490
- Release Date:2018/08/22 16:27
-
Connect the external potentiometer to the terminals 10, 2, and 5 of the first inverter (be sure to connect the variable terminal to the terminal 2). Connect ... More Details >>
- No:21462
- Release Date:2018/08/22 16:27
-
Inverter current characteristics
In general, relationship between T (torque), K (constant), V (voltage), I (current), and F (frequency) is expressed as "T = K × (V/F) × I". Since (V/F) is co... More Details >>
- No:21505
- Release Date:2018/08/22 16:28
-
The servo motor provides the highest precision and response.With the vector inverter, position control using pulse train input ensures position control at pr... More Details >>
- No:22036
- Release Date:2018/08/22 16:30
-
Cycle operation mode, continuous operation mode, torque characteristic selection
When using a motor with an encoder by performing auto tuning, you need to choose the operation mode or continuous operation mode depending on the application... More Details >>
- No:21661
- Release Date:2018/08/22 16:28
-
Unwinding using vector inverter
1. Torque control automatically adjust the speed so that the instructed torque value is maintained. This means that the speed is not controlled. (However, yo... More Details >>
- No:21420
- Release Date:2018/08/22 16:27
-
By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>
- No:21664
- Release Date:2018/08/22 16:28
21-30 of Total 51