Yes. "OL" is displayed under speed control whenever the torque limit is reached without regard to the rated torque. More Details >>
- No:21448
- Release Date:2018/08/22 16:27
-
Operation under torque limit in the speed control mode
Under a 50% torque limit, if the commanded speed (50 Hz in your example) cannot be achieved without torque exceeding 50%, since the torque does not exceed th... More Details >>
- No:21483
- Release Date:2018/08/22 16:27
-
It is considered that conditions including the power supply and noise change whether the parameter unit is connected or disconnected, influencing the analog ... More Details >>
- No:21454
- Release Date:2018/08/22 16:27
-
Use of general-purpose servo motor
You can operate it by adjusting the motor constant by the auto tuning function. (Note that the same characteristics as operated by the servo amplifier MR-VA ... More Details >>
- No:21652
- Release Date:2018/08/22 16:28
-
When a vector inverter is used for position control, the servo lock works when it is stopped. When the start signal (STF or STR) is turned ON, the servo lock... More Details >>
- No:21502
- Release Date:2018/08/22 16:28
-
Just by adding this option, encoder pulses connected to the inverter or option are output.You can also divide the pulse train output. More Details >>
- No:22062
- Release Date:2018/08/22 16:30
-
It is necessary for vector control operation. Use a dedicated motor or a motor with an encoder. If you use another manufacturer's motor, use an encoder capab... More Details >>
- No:21650
- Release Date:2018/08/22 16:28
-
Connect the external potentiometer to the terminals 10, 2, and 5 of the first inverter (be sure to connect the variable terminal to the terminal 2). Connect ... More Details >>
- No:21462
- Release Date:2018/08/22 16:27
-
We do not offer a geared motor. More Details >>
- No:21647
- Release Date:2018/08/22 16:28
-
The following amount of heat is generated under the 100% load. (The same amount for both the 200 V and 400 V classes. The amount of heat generated by the bui... More Details >>
- No:21568
- Release Date:2018/08/22 16:28