  • Encoder cable length restriction

    If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>

    • No:21932
    • Release Date:2018/08/22 16:30
  • Position control

    The servo motor provides the highest precision and response.With the vector inverter, position control using pulse train input ensures position control at pr... More Details >>

    • No:22036
    • Release Date:2018/08/22 16:30
  • Encoder signal output

    It can be output by attaching the plug-in option FR-VPA, FR-VPB, or FR-VPC. Note that the output format depends on the option type. FR-VPA: Open collector ou... More Details >>

    • No:21643
    • Release Date:2018/08/22 16:28
  • Encoder

    It is necessary for vector control operation. Use a dedicated motor or a motor with an encoder. If you use another manufacturer's motor, use an encoder capab... More Details >>

    • No:21650
    • Release Date:2018/08/22 16:28
  • Plug-in options

    You cannot reuse the plug-in option for the FREQROL-A200 and A100 series. You must use one of the following three plug-in options dedicated to the FREQROL-V2... More Details >>

    • No:21656
    • Release Date:2018/08/22 16:28
  • Difference from general-purpose inverter

    While the inverter uses open-loop (V/F) control, it uses semi-closed loop vector control (constant current control). This enables output of stable torque esp... More Details >>

    • No:21659
    • Release Date:2018/08/22 16:28
  • Feature

    By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>

    • No:21664
    • Release Date:2018/08/22 16:28
  • Meaning of OL display (2)

    Yes. "OL" is displayed under speed control whenever the torque limit is reached without regard to the rated torque. More Details >>

    • No:21448
    • Release Date:2018/08/22 16:27
  • Rotations per minute vary

    It is considered that conditions including the power supply and noise change whether the parameter unit is connected or disconnected, influencing the analog ... More Details >>

    • No:21454
    • Release Date:2018/08/22 16:27
  • Speed fluctuation

    I use the dedicated motor SF-VR with the same capacity as the inverter. 1. Load fluctuationSpeed fluctuation ratio with the load fluctuation 0 to 100% is:Wit... More Details >>

    • No:21490
    • Release Date:2018/08/22 16:27