  • I want to drive other manufacturer's motor with PG

    You can drive the motor with the FR-V240E-5.5K. However, the following conditions apply: - You need to perform auto tuning because the motor's circuit consta... More Details >>

    • No:21539
    • Release Date:2018/08/22 16:28
  • Pre-excitation, zero-speed control, and servo lock

    Pre-excitation is the process to control current while a motor is stopped so that motor torque can be generated immediately. There are two methods for this p... More Details >>

    • No:21562
    • Release Date:2018/08/22 16:28
  • Encoder signal output

    It can be output by attaching the plug-in option FR-VPA, FR-VPB, or FR-VPC. Note that the output format depends on the option type. FR-VPA: Open collector ou... More Details >>

    • No:21643
    • Release Date:2018/08/22 16:28
  • Encoder

    It is necessary for vector control operation. Use a dedicated motor or a motor with an encoder. If you use another manufacturer's motor, use an encoder capab... More Details >>

    • No:21650
    • Release Date:2018/08/22 16:28
  • Auto tuning

    Vector control performs high-accuracy calculation using the motor constant. Therefore, to perform vector control operation, the inverter must recognize the m... More Details >>

    • No:21663
    • Release Date:2018/08/22 16:28
  • Angular velocity change control

    The inverter itself does not have a function to detect the rotation angle and change the velocity accordingly. Therefore, to implement required control, it i... More Details >>

    • No:22086
    • Release Date:2018/08/22 16:30
  • Position control

    The servo motor provides the highest precision and response.With the vector inverter, position control using pulse train input ensures position control at pr... More Details >>

    • No:22036
    • Release Date:2018/08/22 16:30
  • Meaning of OL display (2)

    Yes. "OL" is displayed under speed control whenever the torque limit is reached without regard to the rated torque. More Details >>

    • No:21448
    • Release Date:2018/08/22 16:27
  • Inverter current characteristics

    In general, relationship between T (torque), K (constant), V (voltage), I (current), and F (frequency) is expressed as "T = K × (V/F) × I". Since (V/F) is co... More Details >>

    • No:21505
    • Release Date:2018/08/22 16:28
  • Speed control range

    1:1500 when using a vector control dedicated motor. Continuous 100% torque operation and short-time 150% torque operation are possible even at 1 rpm. Continu... More Details >>

    • No:21662
    • Release Date:2018/08/22 16:28