  • Encoder cable length restriction

    If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>

    • No:21932
    • Release Date:2018/08/22 16:30
  • Reusing parameter units

    You cannot reuse the parameter unit (FR-PU01) for the FREQROL-Z series, the parameter unit (FR-PU02) for the FREQROL-A200 and A100 series, and the parameter ... More Details >>

    • No:21654
    • Release Date:2018/08/22 16:28
  • Automatic restart after instantaneous power failure

    The inverter has the automatic restart after instantaneous power failure function. By setting Pr.61 to other than "9999", the encoder detects the speed of th... More Details >>

    • No:21642
    • Release Date:2018/08/22 16:28
  • Motor characteristics at low input voltage

    Since the dedicated motor is designed with the rated voltage of approximately 320 V, it can produce sufficient torque for the input voltage of 380 V. Therefo... More Details >>

    • No:21434
    • Release Date:2018/08/22 16:27
  • Meaning of OL display (2)

    Yes. "OL" is displayed under speed control whenever the torque limit is reached without regard to the rated torque. More Details >>

    • No:21448
    • Release Date:2018/08/22 16:27
  • Inverter current characteristics

    In general, relationship between T (torque), K (constant), V (voltage), I (current), and F (frequency) is expressed as "T = K × (V/F) × I". Since (V/F) is co... More Details >>

    • No:21505
    • Release Date:2018/08/22 16:28
  • Rotations per minute vary

    It is considered that conditions including the power supply and noise change whether the parameter unit is connected or disconnected, influencing the analog ... More Details >>

    • No:21454
    • Release Date:2018/08/22 16:27
  • Feature

    By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>

    • No:21664
    • Release Date:2018/08/22 16:28
  • Applicable motors

    In addition to the dedicated motor (SF-VR series), the SF-JR series motor with an encoder can be used. You can also use a standard motor by combining it with... More Details >>

    • No:21653
    • Release Date:2018/08/22 16:28
  • Connecting potentiometer

    Connect the external potentiometer to the terminals 10, 2, and 5 of the first inverter (be sure to connect the variable terminal to the terminal 2). Connect ... More Details >>

    • No:21462
    • Release Date:2018/08/22 16:27