  • Encoder cable length restriction

    If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>

    • No:21932
    • Release Date:2018/08/22 16:30
  • Comparison with FR-A200E

    In addition to speed control, you can also select torque control as well as you can perform position control using an option. The speed control range is as l... More Details >>

    • No:21655
    • Release Date:2018/08/22 16:28
  • Amount of heat generated

    The following amount of heat is generated under the 100% load. (The same amount for both the 200 V and 400 V classes. The amount of heat generated by the bui... More Details >>

    • No:21568
    • Release Date:2018/08/22 16:28
  • CC-Link

    The inverters FR-A200 and V200 do not support CC-Link. (The FR-A500 series supports CC-Link.) Use the open collector output and relay output card when combin... More Details >>

    • No:21504
    • Release Date:2018/08/22 16:28
  • Unwinding using vector inverter

    1. Torque control automatically adjust the speed so that the instructed torque value is maintained. This means that the speed is not controlled. (However, yo... More Details >>

    • No:21420
    • Release Date:2018/08/22 16:27
  • Angular velocity change control

    The inverter itself does not have a function to detect the rotation angle and change the velocity accordingly. Therefore, to implement required control, it i... More Details >>

    • No:22086
    • Release Date:2018/08/22 16:30
  • Position control

    The servo motor provides the highest precision and response.With the vector inverter, position control using pulse train input ensures position control at pr... More Details >>

    • No:22036
    • Release Date:2018/08/22 16:30
  • Feature

    By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>

    • No:21664
    • Release Date:2018/08/22 16:28
  • Auto tuning

    Vector control performs high-accuracy calculation using the motor constant. Therefore, to perform vector control operation, the inverter must recognize the m... More Details >>

    • No:21663
    • Release Date:2018/08/22 16:28
  • Speed control range

    1:1500 when using a vector control dedicated motor. Continuous 100% torque operation and short-time 150% torque operation are possible even at 1 rpm. Continu... More Details >>

    • No:21662
    • Release Date:2018/08/22 16:28