FAQ within [ FREQROL-V200 ]

31-40 of Total 52

prev 4 / 6page next
  • Small capacity vector inverter dedicated motor

    We offer 5.5 kW or higher SF-VR dedicated motors and do not offer small capacity (3.7 kW or lower) motors. If you need small capacity (1.5 kW to 3.7 kW), use... More Details >>

    • No:21648
    • Release Date:2018/08/22 16:28
  • Manufacturing of 6P dedicated motor

    We cannot manufacture a 6P by SF-VR dedicated motor. Use a motor with 6P encoder. More Details >>

    • No:21646
    • Release Date:2018/08/22 16:28
  • Amount of heat generated

    The following amount of heat is generated under the 100% load. (The same amount for both the 200 V and 400 V classes. The amount of heat generated by the bui... More Details >>

    • No:21568
    • Release Date:2018/08/22 16:28
  • Feature

    By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>

    • No:21664
    • Release Date:2018/08/22 16:28
  • Auto tuning

    Vector control performs high-accuracy calculation using the motor constant. Therefore, to perform vector control operation, the inverter must recognize the m... More Details >>

    • No:21663
    • Release Date:2018/08/22 16:28
  • Motor wiring length

    Up to 50 m. Be sure to connect the encoder cables in parallel and use the thicker cable gauge. You can extend this distance up to 100 m by using the long dis... More Details >>

    • No:21641
    • Release Date:2018/08/22 16:28
  • Can I change the carrier frequency?

    You can change it by changing the setting of Pr.72 (PWM frequency selection). Setting range of Pr.72: 0, 1, 2, 3, 4, 5, 6 (Initial setting is "6".) (The smal... More Details >>

    • No:21640
    • Release Date:2018/08/22 16:28
  • Reset selection

    The specifications of the FR-V200E series do not allow for choosing from "Reset input always enabled" and "Reset input enabled only when the protective funct... More Details >>

    • No:22031
    • Release Date:2018/08/22 16:30
  • Encoder cable length restriction

    If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>

    • No:21932
    • Release Date:2018/08/22 16:30
  • Regeneration unit

    You can reuse the brake units used with the FR-A series, including the FR-RC power regeneration converter, FR-BU, and BU brake unit. You can also use the hig... More Details >>

    • No:21658
    • Release Date:2018/08/22 16:28