  • Motor characteristics at low input voltage

    Since the dedicated motor is designed with the rated voltage of approximately 320 V, it can produce sufficient torque for the input voltage of 380 V. Therefo... More Details >>

    • No:21434
    • Release Date:2018/08/22 16:27
  • Speed control range

    1:1500 when using a vector control dedicated motor. Continuous 100% torque operation and short-time 150% torque operation are possible even at 1 rpm. Continu... More Details >>

    • No:21662
    • Release Date:2018/08/22 16:28
  • Inverter current characteristics

    In general, relationship between T (torque), K (constant), V (voltage), I (current), and F (frequency) is expressed as "T = K × (V/F) × I". Since (V/F) is co... More Details >>

    • No:21505
    • Release Date:2018/08/22 16:28
  • Manufacturing of 6P dedicated motor

    We cannot manufacture a 6P by SF-VR dedicated motor. Use a motor with 6P encoder. More Details >>

    • No:21646
    • Release Date:2018/08/22 16:28
  • Speed fluctuation

    I use the dedicated motor SF-VR with the same capacity as the inverter. 1. Load fluctuationSpeed fluctuation ratio with the load fluctuation 0 to 100% is:Wit... More Details >>

    • No:21490
    • Release Date:2018/08/22 16:27
  • Cycle operation mode, continuous operation mode, torque characteristic selection

    When using a motor with an encoder by performing auto tuning, you need to choose the operation mode or continuous operation mode depending on the application... More Details >>

    • No:21661
    • Release Date:2018/08/22 16:28
  • Comparison with FR-A200E

    In addition to speed control, you can also select torque control as well as you can perform position control using an option. The speed control range is as l... More Details >>

    • No:21655
    • Release Date:2018/08/22 16:28
  • Torque control accuracy

    Since the torque control accuracy is influenced by change of motor temperature:- Standard product???±5% (at 75 deg C) ±0.5%/deg C of rated torque- Combinatio... More Details >>

    • No:21645
    • Release Date:2018/08/22 16:28
  • Speed fluctuation ratio

    1. Speed fluctuation ratio when using the FR-V200 + dedicated motor (with an encoder) The vector inverter FR-V200 detects speed by the encoder and speed fluc... More Details >>

    • No:21489
    • Release Date:2018/08/22 16:27
  • Explosion countermeasure

    We do not offer an explosion-proof type of vector inverter. More Details >>