  • Model configuration

    12 models of FREQROL-V200 vector inverters each for the 200 V and 400 V classes from 1.5K to 45K. 9 models of SF-VR vector control dedicated motors each for ... More Details >>

    • No:21657
    • Release Date:2018/08/22 16:28
  • Feature

    By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>

    • No:21664
    • Release Date:2018/08/22 16:28
  • Pre-excitation, zero-speed control, and servo lock

    Pre-excitation is the process to control current while a motor is stopped so that motor torque can be generated immediately. There are two methods for this p... More Details >>

    • No:21562
    • Release Date:2018/08/22 16:28
  • Comparison with FR-A200E

    In addition to speed control, you can also select torque control as well as you can perform position control using an option. The speed control range is as l... More Details >>

    • No:21655
    • Release Date:2018/08/22 16:28
  • Inverter current characteristics

    In general, relationship between T (torque), K (constant), V (voltage), I (current), and F (frequency) is expressed as "T = K × (V/F) × I". Since (V/F) is co... More Details >>

    • No:21505
    • Release Date:2018/08/22 16:28
  • Position control

    The servo motor provides the highest precision and response.With the vector inverter, position control using pulse train input ensures position control at pr... More Details >>

    • No:22036
    • Release Date:2018/08/22 16:30
  • Plug-in options

    You cannot reuse the plug-in option for the FREQROL-A200 and A100 series. You must use one of the following three plug-in options dedicated to the FREQROL-V2... More Details >>

    • No:21656
    • Release Date:2018/08/22 16:28
  • Connecting potentiometer

    Connect the external potentiometer to the terminals 10, 2, and 5 of the first inverter (be sure to connect the variable terminal to the terminal 2). Connect ... More Details >>

    • No:21462
    • Release Date:2018/08/22 16:27
  • Difference from general-purpose inverter

    While the inverter uses open-loop (V/F) control, it uses semi-closed loop vector control (constant current control). This enables output of stable torque esp... More Details >>

    • No:21659
    • Release Date:2018/08/22 16:28
  • Vector inverter option

    Just by adding this option, encoder pulses connected to the inverter or option are output.You can also divide the pulse train output. More Details >>