  • Torque control accuracy

    Since the torque control accuracy is influenced by change of motor temperature:- Standard product???±5% (at 75 deg C) ±0.5%/deg C of rated torque- Combinatio... More Details >>

    • No:21645
    • Release Date:2018/08/22 16:28
  • Unwinding using vector inverter

    1. Torque control automatically adjust the speed so that the instructed torque value is maintained. This means that the speed is not controlled. (However, yo... More Details >>

    • No:21420
    • Release Date:2018/08/22 16:27
  • Pre-excitation, zero-speed control, and servo lock

    Pre-excitation is the process to control current while a motor is stopped so that motor torque can be generated immediately. There are two methods for this p... More Details >>

    • No:21562
    • Release Date:2018/08/22 16:28
  • Coasting to stop method

    Use Pr.17 (Input terminal assignment) to assign MRS to the terminals DI1, DI2, and DI3. More Details >>

    • No:21937
    • Release Date:2018/08/22 16:30
  • Connecting potentiometer

    Connect the external potentiometer to the terminals 10, 2, and 5 of the first inverter (be sure to connect the variable terminal to the terminal 2). Connect ... More Details >>

    • No:21462
    • Release Date:2018/08/22 16:27
  • Reset selection

    The specifications of the FR-V200E series do not allow for choosing from "Reset input always enabled" and "Reset input enabled only when the protective funct... More Details >>

    • No:22031
    • Release Date:2018/08/22 16:30
  • Position control

    The servo motor provides the highest precision and response.With the vector inverter, position control using pulse train input ensures position control at pr... More Details >>

    • No:22036
    • Release Date:2018/08/22 16:30
  • Vector inverter option

    Just by adding this option, encoder pulses connected to the inverter or option are output.You can also divide the pulse train output. More Details >>

    • No:22062
    • Release Date:2018/08/22 16:30
  • Regeneration unit

    You can reuse the brake units used with the FR-A series, including the FR-RC power regeneration converter, FR-BU, and BU brake unit. You can also use the hig... More Details >>

    • No:21658
    • Release Date:2018/08/22 16:28
  • Cycle operation mode, continuous operation mode, torque characteristic selection

    When using a motor with an encoder by performing auto tuning, you need to choose the operation mode or continuous operation mode depending on the application... More Details >>

    • No:21661
    • Release Date:2018/08/22 16:28