FAQ within [ FREQROL-V200 ]

1-10 of Total 52

prev 1 / 6page next
  • Comparison with FR-A200E

    In addition to speed control, you can also select torque control as well as you can perform position control using an option. The speed control range is as l... More Details >>

    • No:21655
    • Release Date:2018/08/22 16:28
  • Inverter current characteristics

    In general, relationship between T (torque), K (constant), V (voltage), I (current), and F (frequency) is expressed as "T = K × (V/F) × I". Since (V/F) is co... More Details >>

    • No:21505
    • Release Date:2018/08/22 16:28
  • I want to drive other manufacturer's motor with PG

    You can drive the motor with the FR-V240E-5.5K. However, the following conditions apply: - You need to perform auto tuning because the motor's circuit consta... More Details >>

    • No:21539
    • Release Date:2018/08/22 16:28
  • Model configuration

    12 models of FREQROL-V200 vector inverters each for the 200 V and 400 V classes from 1.5K to 45K. 9 models of SF-VR vector control dedicated motors each for ... More Details >>

    • No:21657
    • Release Date:2018/08/22 16:28
  • Regeneration unit

    You can reuse the brake units used with the FR-A series, including the FR-RC power regeneration converter, FR-BU, and BU brake unit. You can also use the hig... More Details >>

    • No:21658
    • Release Date:2018/08/22 16:28
  • Coasting to stop method

    Use Pr.17 (Input terminal assignment) to assign MRS to the terminals DI1, DI2, and DI3. More Details >>

    • No:21937
    • Release Date:2018/08/22 16:30
  • Explosion countermeasure

    We do not offer an explosion-proof type of vector inverter. More Details >>

    • No:21644
    • Release Date:2018/08/22 16:28
  • Connecting potentiometer

    Connect the external potentiometer to the terminals 10, 2, and 5 of the first inverter (be sure to connect the variable terminal to the terminal 2). Connect ... More Details >>

    • No:21462
    • Release Date:2018/08/22 16:27
  • Speed fluctuation ratio

    1. Speed fluctuation ratio when using the FR-V200 + dedicated motor (with an encoder) The vector inverter FR-V200 detects speed by the encoder and speed fluc... More Details >>

    • No:21489
    • Release Date:2018/08/22 16:27
  • Motor wiring length

    Up to 50 m. Be sure to connect the encoder cables in parallel and use the thicker cable gauge. You can extend this distance up to 100 m by using the long dis... More Details >>

    • No:21641
    • Release Date:2018/08/22 16:28