Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ FREQROL-A200 ]

11-20 of Total 32

prev 2 / 4page next
  • Surge voltage of 400 V inverter

    No. Although the carrier frequency increases or decreases the switching count, the switching speed is the OFF-to-ON speed of the IGBT element of the inverter... More Details >>

    • No:21401
    • Release Date:2018/08/22 16:27
  • Surge voltage of 400 V motor

    When the wire between the 400 V inverter and motor is long (20 m or longer), surge voltage occurs momentarily. This voltage is as two or more times as the DC... More Details >>

    • No:21404
    • Release Date:2018/08/22 16:27
  • Inverter drive of 400 V class motor

    When the wiring between the inverter and motor is long, surge voltage occurs at the terminal of the motor.This surge voltage deteriorates insulation of the m... More Details >>

    • No:21926
    • Release Date:2018/08/22 16:30
  • Driving 200 V motor by 400 V inverter

    A 400 V inverter does not operate when 200 V is supplied to it, therefore the motor does not rotate. A 200 V motor can be rotated by a 400 V inverter, howeve... More Details >>

    • No:21446
    • Release Date:2018/08/22 16:27
  • Power factor improving effect by option

    Installing the high power factor converter brings the power factor improving effect of 99% or higher.Therefore, when the high power factor converter is used,... More Details >>

    • No:22020
    • Release Date:2018/08/22 16:30
  • Speed control failure due to 20 mA from DC 4

    It seems that there is a read error for 20 mA DC inside the inverter.Setting Pr.905 to 50 Hz while 20 mA DC is actually flowing between the terminals 4 and 5... More Details >>

    • No:21998
    • Release Date:2018/08/22 16:30
  • Auto tuning, tuning mode

    The FREQROL-A200 has magnetic flux vector control in addition to the conventional V/F control. Magnetic flux vector control controls the motor with higher ac... More Details >>

    • No:21637
    • Release Date:2018/08/22 16:28
  • CC-Link

    The inverters FR-A200 and V200 do not support CC-Link. (The FR-A500 series supports CC-Link.) Use the open collector output and relay output card when combin... More Details >>

    • No:21504
    • Release Date:2018/08/22 16:28
  • Terminal AM calibration

    1. By setting Pr.158 (Terminal AM function selection) to "21" (Reference voltage output), 10 V is output from the terminal AM.2. Read Pr.901 in the PU operat... More Details >>

    • No:21936
    • Release Date:2018/08/22 16:30
  • UL standard certification number

    The UL standard certification numbers (UL Listing Card No.) of the FR-E500, FR-A500, and FR-A200 are as follows: FR-A200 series??????E131592FR-A500 series???... More Details >>

    • No:21506
    • Release Date:2018/08/22 16:28

11-20 of Total 32