  • Plug-in options

    Use the plug-in option dedicated for the FR-A200EXECLLENT. The plug-in option for the FR-A200EXECLLENT cannot be used with the FR-A200. To avoid installing a... More Details >>

    • No:21634
    • Release Date:2018/08/22 16:28
  • Auto tuning enabled motor

    Auto tuning targets an induction motor. 1. You can perform auto tuning on a wound rotor motor. After performing auto tuning, check operation in test run. 2. ... More Details >>

    • No:21636
    • Release Date:2018/08/22 16:28
  • Communication option

    You can remove the parameter unit FR-PU02 and install the FR-CU01 there. However, since the interface for the parameter unit is used, the communication speed... More Details >>

    • No:21625
    • Release Date:2018/08/22 16:28
  • What functions are added compared with FR-A200?

    The following functions are added or improved: - Auto tuning function- Fast-response current limit operation is improved.- Characteristics of magnetic flux v... More Details >>

    • No:21638
    • Release Date:2018/08/22 16:28
  • Auto tuning, tuning mode

    The FREQROL-A200 has magnetic flux vector control in addition to the conventional V/F control. Magnetic flux vector control controls the motor with higher ac... More Details >>

    • No:21637
    • Release Date:2018/08/22 16:28
  • Current value on input side and output side

    1. When slight imbalance (approximately 5%) is present with the inverter power supply voltage, the inverter input current can get imbalanced significantly. I... More Details >>

    • No:21476
    • Release Date:2018/08/22 16:27
  • Do you have an explosion-proof type?

    We offer the FR-A200E-based pressure-resistant explosion-proof motor driving inverter FR-B series. This series have been certified in the explosion-proof tes... More Details >>

    • No:21630
    • Release Date:2018/08/22 16:28
  • Compatibility of the function with FR-A200

    Yes. Compared with the FR-A200:- The auto tuning function is added.- Response current limit operation is improved.- The carrier frequency range is extended. ... More Details >>

    • No:21629
    • Release Date:2018/08/22 16:28
  • UL standard certification number

    The UL standard certification numbers (UL Listing Card No.) of the FR-E500, FR-A500, and FR-A200 are as follows: FR-A200 series??????E131592FR-A500 series???... More Details >>

    • No:21506
    • Release Date:2018/08/22 16:28
  • Amount of heat generated by inverter

    Refer to Section 2-45 and 2-46 of the FR-A series technical material. More Details >>