- No:22326
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:40
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Using a commercially-available SD memory card for a MELSEC iQ-R series CPU module
For the commercially-available SD memory cards that can be used for MELSEC iQ-R series CPU modules, refer to the following technical bulletin. - TECHNICAL ... More Details >>
- No:22461
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:46
- Category: MELSEC iQ-R Series
-
Security functions of MELSEC iQ-R series
The functions serve to protect the user property stored in a personal computer and the user property inside modules in the MELSEC iQ-R series system against... More Details >>
- No:22481
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:47
- Category: MELSEC iQ-R Series
-
Unable to communicate via USB connection
Check the following points.(1) Transfer Setup is properly configured.(2) The USB driver is properly recognized. More Details >>
- No:22511
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Recommended cables for MODBUS(R) interface module QJ71MB91
The RS-232 cable should meet RS-232 standards and not exceed 15 m in length.The RS-422/485 cable should meet specifications described in the following manual... More Details >>
- No:22566
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Difference between redundant systems and the multiple CPU systems
- Redundant systems A redundant system offers improved system reliability, as it consists of two basic systems, each of which includes a CPU module, powe... More Details >>
- No:22609
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:14
- Category: MELSEC-Q Series
-
No, there is no impact on the command speed.However, the actual acceleration/deceleration time are affected by the change. More Details >>
-
Yes. You can check the servo status through the following monitor data. • "[Md.108] Servo status 1" • "[Md.119] Servo status 2" • "[Md.125] Servo status 3... More Details >>
-
The following shows the initialization procedure. (1) Turn OFF the PLC ready flag. (2) Turn ON "[Cd.2] Parameter initialization request". [QD75M, QD75MH, LD... More Details >>
-
Torque is limited by the lower set value of "[Pr.17] Torque limit setting value" and "[Cd.22] New torque value/forward new torque value".When the current tor... More Details >>