RS-232 adapter cable disconnection prevention
Yes. More Details >>
- No:22799
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Simultaneous broadcast transmission setting for built-in Ethernet port LCPU
To send simultaneous broadcast using UDP, set the parameters as follows.- Destination IP Address: FF.FF.FF.FFh - Destination Port Number: Other than FFFFh (S... More Details >>
- No:22785
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Application of RS-232 adapter L6ADP-R2
This adapter is used to add a serial port to the L series CPU. It is not a serial communication module. It is used for serial communication between a device ... More Details >>
- No:22778
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Simultaneous use of simple PLC communication function and socket communication
The socket communication can be used simultaneously with the simple PLC communication function. More Details >>
- No:22740
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
LCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices.- Protocol: "UDP"- Open System: "MELSOFT connection" More Details >>
- No:22739
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Boot operation from the standard ROM
The boot operation from the standard ROM is not possible. The program memory of LCPU is a flash ROM. Thus, writing in the program memory achieves a ROM opera... More Details >>
- No:22728
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
A/D conversions performed by Q64AD/Q68ADV/Q68ADI
(1) Sampling processing - Without the temperature drift compensation function Processing time = Number of channels usedx 80 (us/1 channel) - With the t... More Details >>
- No:22705
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:34
- Category: MELSEC-Q Series
-
How to specify intelligent function module devices
For "U**", set the first two digits of the start I/O number of an intelligent function module in three-digit representation.Example) For X/Y1F0, set "U1F". More Details >>
- No:22704
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Speeds of access to file registers
If file registers are registered in the standard RAM and "R" is specified by an instruction, the processing time is the same as is the case with the internal... More Details >>
- No:22688
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Setting of "Target MODBUS(R) device head number"
Set "(Last five digits of actual device number) - 1" for the Target MODBUS(R) device head number.Example) For the holding register 400018, set "17". More Details >>
- No:22682
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
591-600 of Total 1123