Relay life of the MELSEC iQ-R series relay output module (RY10R2)
The mechanical life of the module is 20 million times or longer. The relay life (contact switching life) of the module varies depending on the usage environ... More Details >>
- No:22457
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:12
- Category: MELSEC iQ-R Series
-
You can use the MELSEC iQ-R series inter-module synchronization function together with the CC-Link IE Field Network synchronous communication function.With ... More Details >>
- No:22462
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:51
- Category: MELSEC iQ-R Series
-
How to use file registers R in the Q series
File registers R can be used for data whose size is exceeding 32k points with RSET instruction, which is a block switching instruction. Use file registers... More Details >>
- No:22525
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:29
- Category: MELSEC-Q Series
-
Difference between C Controller module and programmable controller CPU module
- C Controller module: Programs are created using C and C++ languages. The programs run based on each task and parallel processing of multiple tasks base... More Details >>
- No:22542
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:05
- Category: MELSEC-Q Series
-
Behavior of sequence program in event of momentary power failure in QCPU
(1) When a momentary power failure occurs for a period not longer than the allowable momentary power failure time When the momentary power failure occurs, t... More Details >>
- No:22587
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:41
- Category: MELSEC-Q Series
-
The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors.(1) The module that has been specified by a FROM/TO instr... More Details >>
- No:22830
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
MX Component Version 4's compatibility with 64-bit Windows 7
Yes. More Details >>
- No:22844
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Time out error in the communication test of MX Component
The possible causes are as follows. - Incorrect setting with a personal computer or an Ethernet interface module Check the IP address, network number, sta... More Details >>
- No:22934
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:49
- Category: Engineering Software
-
CC-Link slave station's flashing L.ERR LED
If the L.ERR LED flashes at irregular intervals, it may indicate that no terminating resistor has been connected or the communication is instable due to the ... More Details >>
- No:23001
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Settings for the FX3U-ENET-ADP
GX Works2 with Ver. 1.87R or later is required. More Details >>
- No:24781
- Release Date:2019/02/27 16:10
- Category: MELSEC-F Series , Engineering Software , Network/Communication