Change the direction with "[PA14] Rotation direction selection/travel direction selection". More Details >>
-
Set the torque limit value in "[Cd.101] Torque output setting value" before the positioning start.The values of "[Pr.17] Torque limit setting value" and "[Cd... More Details >>
-
Yes. (1) Absolute system (a) When the software stroke limit is invalid Positioning is carried out in a designated direction by "[Cd.40] ABS direction in deg... More Details >>
-
The following shows the initialization procedure. (1) Turn OFF the PLC ready flag. (2) Turn ON "[Cd.2] Parameter initialization request". Set "1" to the buff... More Details >>
-
Scan time while operation of a programmable controller CPU is being monitored using GX Works2
Scan time displayed on GX Works2 is the maximum scan time of the monitor target programmable controller CPU. To check current scan time, monitor the data in... More Details >>
- No:24779
- Release Date:2019/02/27 15:58
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Connecting local stations to the FX3U-16CCL-M
No, local stations cannot be connected to the FX3U-16CCL-M. Remote I/O stations, remote device stations, and intelligent device stations can be connected to... More Details >>
- No:24791
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Network/Communication
-
Assignment of input/output numbers (MELSEC-F series)
Octal numbers are assigned as input/output numbers for the MELSEC-F series. The octal number system uses the digits from 0 to 7 → from 10 to 17 → from 20 to... More Details >>
- No:24868
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Setting of the FX3U-ENET-ADP Ethernet communication special adapter
GX Works2 with Ver. 1.90U or later can be used for the setting of the FX3U-ENET-ADP. More Details >>
- No:24875
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Network/Communication
-
Whether the positioning parameter is used or the extension positioning parameter is used can be selected in BFM#32 (positioning parameter selection). Select ... More Details >>
- No:24917
- Release Date:2019/04/17 11:40
- Category: MELSEC-F Series , Positioning Control
-
Adding two channels of the RS-232C port in the FX3G series
Select the 40-point or 60-point type FX3G series main unit. In this case, two FX3G-232-BDs can be connected. When FX3G-CNV-ADP is used, anFX3U-232ADP can be ... More Details >>
- No:24926
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
741-750 of Total 1048