FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Differences between the FX3UC-32MT-LT and the FX3UC-32MT-LT2
The built-in CC-Link/LT setting differs. For the FX3UC-32MT-LT, the built-in CC-Link/LT setting is performed with the DIP switch. For the FX3UC-32MT-LT2, th... More Details >>
- No:24956
- Release Date:2019/04/18 14:28
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Regarding the driving contacts of high-speed counter instructions
The current value of the high-speed counter is retained and will not be cleared. More Details >>
- No:39304
- Release Date:2023/02/13 16:40
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding communication data code for SLMP communication
It can not be set for each connection. More Details >>
- No:39312
- Release Date:2023/02/14 08:55
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding Display Module Support
In the iQ-F series, there is no lineup of display modules. Consider usingweb server function. More Details >>
- No:40045
- Release Date:2023/08/24 15:53
- Update:2023/08/24 15:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Input Response Frequency Difference between FX5-2HC/ES and Conventional Model (FX3U-2HC)
The input response frequencies of the FX5-2HC/ES and FX3U-2HC differ as shown below. FX5-2HC/ES・・・2MHz FX3U-2HC・・・200kHz More Details >>
- No:44340
- Release Date:2024/03/20 13:31
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding how to generate a false error
There is no function to generate a false error. For example, if operand (s2): divisor is set to "0" in the division command and the command is executed, err... More Details >>
- No:44610
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding printing of cross-references
If cross-references are displayed on GX Works3, you can print them. More Details >>
- No:44619
- Release Date:2024/11/28 16:10
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Make sure to turn off the power of the programmable controller before replacing the battery. Replacing the battery while the power of the programmable con... More Details >>
- No:22509
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:24
- Category: MELSEC-Q Series
-
How to display the list of device comments in GX Works2
Double-click "Global Device Comment" in the Project view to display the list. More Details >>
- No:22606
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
I cannot open a project file of PX Developer.
When the total number of characters in the drive/path and project name exceeds 149 one-byte characters (74 two-byte characters), the message "The drive path ... More Details >>
- No:22947
- Release Date:2018/09/03 17:30
- Update:2018/09/25 10:58
- Category: Engineering Software
791-800 of Total 1123