FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
How refresh devices for CC-Link remote inputs and outputs are assigned
The refresh device setting of the CC-Link parameter assigns any devices to the I/O numbers greater than those assigned to the modules on the same base unit. ... More Details >>
- No:22968
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Communication between a CC-Link master station and local stations
There are two modes of transient transmission, cyclic transmission and transient transmission, for the communication between a master station and a local sta... More Details >>
- No:23006
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:53
- Category: Network related products
-
File format that can be saved to a CF card in the FX3U-CF-ADP
CSV file can be saved. More Details >>
- No:24938
- Release Date:2019/04/18 14:24
- Category: MELSEC-F Series , Main Unit , Accessories
-
Regarding QoS, Retain, Will, and Clean Session Functions for MQTT Communications
The QoS, Retain, Will, and Clean Session functions of the MQTT communication function can not be configured in buffer memory. Module FB: M+FX5ENET. QoS ca... More Details >>
- No:40053
- Release Date:2023/08/25 09:21
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Always-On Special Relay Numbers
It is SM400. More Details >>
- No:44986
- Release Date:2025/05/08 09:08
- Category: MELSEC MX Controller MX-F Model
-
Regarding the maximum number of channels of high-speed counters
The FX5 CPU module's built-in high-speed counter can control up to 8CH. Up to 16CH can be controlled by adding 4 modules of FX5-16ET/E□-H (high-speed pulse ... More Details >>
- No:22311
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:34
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Battery replacement for universal model QCPU
The contents of the standard RAM and latch devices are not erased if the battery replacement is completed within three minutes, which is the backup power tim... More Details >>
- No:22558
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
MX Component Version 4's compatibility with 64-bit Windows 7
Yes. More Details >>
- No:22844
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Compatibility between the Japanese and English versions of GX Developer
All the components other than comments in Japanese are supported. Ladder programs and parameters can be used as they are, whether or not they are created usi... More Details >>
- No:22848
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
GX Developer's compatibility with QnUDVCPU
GX Developer does not support QnUDVCPU. Please use GX Works2 instead. More Details >>
- No:22885
- Release Date:2018/09/03 17:30
- Category: Engineering Software