MODE switch setting for QJ61BT11N
The MODE switch can set the following modes.- 0 to 4: Online mode- 5 to 9: Line test mode- A to E: Hardware test modeEach mode in ascending order of set valu... More Details >>
- No:23025
- Release Date:2018/09/03 17:31
- Category: Network related products
-
The thickness of wireshould be2 square millimeters or more, andclass D grounding (grounding resistance: 100 Ω or less) should be performed. More Details >>
- No:24899
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Main Unit
-
Index modifier of the bit device in the FX3GC series
FX3GC series does not support the index modifier for the bit devices. FX3U/FX3UC series supports it. More Details >>
- No:25002
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Regarding program execution using SD Memory Cards
It's possible. Use the boot operation function of the SD memory card. *To use the boot operation function with the FX5S CPU module, you need to install an a... More Details >>
- No:39311
- Release Date:2023/02/14 08:54
- Category: MELSEC iQ-F Series , Option , CPU Module
-
How to read projects created by GX Works2 in GX Developer
Select [Project] -> [Export to GX Developer Format File] and save the project so that it can be opened in GX Developer.For more details, refer to GX Works... More Details >>
- No:22515
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
It means that in an ambient temperature of 25 degrees Celsius, an error per day falls within the range of "delay of 2.57s" to "advance of 5.27s". "TYP.+2.22... More Details >>
- No:22651
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:53
- Category: MELSEC-Q Series
-
MX Sheet Version 2's compatibility with 64-bit Windows 7
Yes. More Details >>
- No:22866
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
CC-Link signals checked when an error occurs
Check the following signals.- Module error signal : X0- Host data link status signal: X1- Other station data link status signal: X3 More Details >>
- No:23021
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Difference in specifications between CC-Link versions
Ver.1.10 is a standard where CC-Link station-to-station cable length restriction in Ver. 1.00 has been removed, and the length of all station-to-station cabl... More Details >>
- No:22975
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Link data from communication error stations in a CC-Link network
The remote input RX of the master station and the remote input RX and remote output RY of local stations clear/hold the data from an error station according ... More Details >>
- No:23057
- Release Date:2018/09/03 17:31
- Category: Network related products