Difference between QJ61BT11 and QJ61BT11N
QJ61BT11N supports Version 2 (expanded cyclic setting), the setting for refreshing/forced clearing a slave station data when the switch on a programmable con... More Details >>
- No:22964
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:16
- Category: Network related products
-
M384 to M1535 and D128 to D1099 can be latched. M1536 to M7679, D1100 to D7999, and R0 to R23999 can be used as latch areas by installing an optional batt... More Details >>
- No:24703
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
Index modifier of bit devices in the FX3G series
The FX3G series does not support the index modifier for the bit devices. The FX3U/FX3UC series supports this function. More Details >>
- No:24959
- Release Date:2019/04/18 14:35
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding clearing error with SM50
It is cleared by eliminating the cause of the error during detection and turning on SM50. For the error codes that can be cleared on the SM50, refer to the ... More Details >>
- No:39292
- Release Date:2023/02/13 15:37
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the maximum number of controllable axes of the bulit-in positioning function
Up to 4 axes can be controlled. Please use a transistor output type CPU module. (By adding a high speed pulse input/output module, maximum 12 axes (CPU bui... More Details >>
- No:22300
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:52
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding MODBUS/TCP communication of the built-in Ethernet port
When used as a master station, communication with a slave station can be performed using the simple CPU communication or the predefined protocol support func... More Details >>
- No:22302
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:52
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the system configuration of FX5-CCL-MS with FX5 CPU module
A total of two FX5-CCL-MS (CC-Link system master/intelligent device) can be connected: one as a master station and one as an intelligent device station. More Details >>
- No:22318
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:50
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
PLC type change in GX Developer
Follow the steps below and then execute PLC type change.- On the menu of GX Developer, select [Online] -> [Monitor] -> [Stop Monitoring (All Windows)],... More Details >>
- No:22522
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Turning ON/OFF annunciators (F)
The data in the special registers SD62 to SD79 change with the following process. - Turn ON the registers with OUT and SET instructions. - Turn OFF the r... More Details >>
- No:22649
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:45
- Category: MELSEC-Q Series
-
The cross reference window is not displayed.
Select [View]-> [Cross reference window] from the menu in GX Developer to display the cross reference window. More Details >>
- No:22951
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:54
- Category: Engineering Software