FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Mixing the CC-Link IE Field Network with general LAN communication
Mixed communication with the same hub cannot be established. Establish the CC-Link IE Field Network and general LAN communication separately. More Details >>
- No:22988
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:48
- Category: Network related products
-
Difference between QH42P and QX41Y41P
The difference is I/O numbers used for input and output (XY). QH42P uses the same I/O numbers both for input and output. QX41Y41P uses sequential I/O numbers... More Details >>
- No:22539
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
How to write comments of GX Works2 into the standard ROM
Switch the Target Memory to "Standard ROM" in the "Write to PLC" window. More Details >>
- No:22611
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Production of Q61P-A1 and Q61P-A2
They have gone out of production. However, Q61P, a succeeding model, can be used in the same way. More Details >>
- No:22655
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Using a commercially-available SD memory card for a MELSEC iQ-R series CPU module
For the commercially-available SD memory cards that can be used for MELSEC iQ-R series CPU modules, refer to the following technical bulletin. - TECHNICAL ... More Details >>
- No:22461
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:46
- Category: MELSEC iQ-R Series
-
Duplication error in a CC-Link master station
Possible causes are as follows.(1) Another master station exists on the same line.(2) Noise is detected on the line at power on. More Details >>
- No:23044
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Precaution about MELSECNET/H connection (2)
- Set the network module mounted in system A to station number 0 (multiplexed remote master station). Set the network module mounted in system B to any sta... More Details >>
- No:23054
- Release Date:2018/09/03 17:31
- Update:2018/09/26 11:00
- Category: Network related products
-
Regarding differences between instance communication and tag communication
Instance communication ・The instance ID (any number) is used to communicate with the other device. Tag communication ・The tag name (any character string) ... More Details >>
- No:45486
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Error code H1968 of FX5-ENET Mail send FB
"The number of characters specified in the input label: i_uBodyLength (number of characters in the body) is different from the number of characters in the bo... More Details >>
- No:44607
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Memory allocation for online change
The scan time may be substantially longer. Continue the operation if there is no problem with the longer scan time. More Details >>
- No:22575
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:01
- Category: MELSEC-Q Series
1-10 of Total 1023