Change timing of the status of A/D conversion module's I/O signals
(1)If the A/D conversion enable signal is kept ON, conversion processing is kept performed. Once conversion processing is successfully performed, A/D conve... More Details >>
- No:22710
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:12
- Category: MELSEC-Q Series
-
Setting of "Target MODBUS(R) device head number"
Set "(Last five digits of actual device number) - 1" for the Target MODBUS(R) device head number.Example) For the holding register 400018, set "17". More Details >>
- No:22682
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to check errors in a CC-Link master station
When an error has occurred in the master station (including the standby master station), the data link control cannot be performed, and you cannot check erro... More Details >>
- No:23078
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Including GX Developer in GX Works2
Yes, it does.GX Developer can be installed along with the installation of GX Works2.For more details of the installation procedure, refer to GX Works2 Versio... More Details >>
- No:22506
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Connect with a straight cable using a hub. For more details, refer to the following manual. - FL-net (OPCN-2) Interface Module User's Manual More Details >>
- No:22574
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:55
- Category: MELSEC-Q Series
-
USB cable type for CPU modules
It is type B. More Details >>
- No:22622
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Accessing file registers from the built-in Ethernet port QCPU using A-compatible 1E frames
The QnUDE(H)CPU modules with serial numbers with upper 5 digits of "14112" or later indicate compatibility with the function. The accessible device range is ... More Details >>
- No:22645
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Production of Q61P-A1 and Q61P-A2
They have gone out of production. However, Q61P, a succeeding model, can be used in the same way. More Details >>
- No:22655
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
GX Developer's compatibility with 32-bit Windows 7
GX Developer Version 8.91V or later supports 32-bit Windows 7. More Details >>
- No:22660
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Print settings of the device list in GX Works2
When [Display Option] -> [Used devices] -> [Contact] and [Coil] are selected in the Device List window, devices used are not displayed. More Details >>
- No:22661
- Release Date:2018/09/03 17:29
- Update:2018/09/21 12:18
- Category: MELSEC-Q Series