Regarding how to check the date of manufacture
The date of manufacture of a product can be confirmed by the following methods. ① Name plate verification There is a name plate on the right side of the pr... More Details >>
- No:44878
- Release Date:2025/03/18 11:11
- Category: MELSEC iQ-F Series , CPU Module
-
Difference between GX Works2 and GX Developer
Main differences between GX Works2 and GX Developer are as follows:-The functions of GX Configurator and GX Simulator are integrated as GX Works2. No additio... More Details >>
- No:22503
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
The error code "4100" is "OPERATION ERROR". The error occurs when a number is divided by 0 (Divisor D6268 value is 0). Make modifications so that the divis... More Details >>
- No:22533
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:43
- Category: MELSEC-Q Series
-
How to open a GXW file in GX Works2
A file with the GXW extension is a project in the single file format.GX Works2 Version 1.62Q or later supports projects in the single file format. More Details >>
- No:22508
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Regarding the default IP address
The default IP address (factory default value) of FX5CPU modules is 192.168.3.250. More Details >>
- No:22290
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:33
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Deleting all programs and data from the memory
Data can be cleared from GX Developer or GX Works2. [Online]→Select all [PLC memory], [Data device], and [Bit device.] on the Clear PLC memory window, and e... More Details >>
- No:22269
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Displaying comments in GX Works2
Select [View] -> [Comment] from the menu to display comments. You can display local comments with the following procedure. (1) Select [Tool] -> [Op... More Details >>
- No:22941
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:58
- Category: Engineering Software
-
The "S/S" terminal is used to switch the input type (sink input and source input). For the source input, connect the "S/S" terminal to the "0V" terminal, a... More Details >>
- No:22255
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is th... More Details >>
- No:22535
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:46
- Category: MELSEC-Q Series
-
Regarding how to check MAC Addresses
You can check the MAC address from the name plate on the side of the CPU module or by the Module diagnostics (CPU diagnostics) of GX Works3. More Details >>
- No:39294
- Release Date:2023/02/13 15:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
1-10 of Total 1023