Automatically assigned devices in GX Works2
Yes.Beginning with the device in the "Device/Label Automatic-Assign Setting" window, devices are assigned in descending order (from the greatest device numbe... More Details >>
- No:22846
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding automatic transfer of Data Logging Files
Data logging file transfer (FTP server auto transfer) is supported with the following firmware versions. ・FX5U/FX5UC CPU Module Ver. 1.300 or later ・FX5U... More Details >>
- No:44334
- Release Date:2024/03/20 13:30
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding number of input/output points when adding safety extension module
It will. It is treated the same as an intelligent module, so it occupies 8 I/O points. The safety input expansion module FX5-SF-8DI4 does not occupy the numb... More Details >>
- No:39314
- Release Date:2023/01/12 16:54
- Category: MELSEC iQ-F Series , CPU Module , Safety Control
-
Connecting a DC power supply type extension unit to an AC power supply type main unit
No, they cannot be connected. Connect the units having the same power supply type. More Details >>
- No:25008
- Release Date:2019/04/23 11:12
- Category: MELSEC-F Series , Main Unit
-
Types of data backup methods (FX3G series)
1. Data backup using an optional battery Built-in RAM data and clock data of a programmable controller are held by using an optional battery. The life of... More Details >>
- No:24701
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
The LCPU error code 4116 is displayed when a built-in I/O instruction that is disabled in the parameter setting is executed. Check for the parameter settings... More Details >>
- No:22807
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
The station number setting is not required for non-protocol communication. More Details >>
- No:24948
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Counting of a built-in high-speed counter
Check that the RST instruction ofthe high-speed counter is not executed whilethe program is running. Forthe high-speed counter which supports the external r... More Details >>
- No:24787
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Engineering Software , Main Unit