FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Editable range of Inline Structured Texts
Up to 2048 characters can be entered in the inline Structured Text box. The limit cannot be increased. Note that a line break is counted as 2 characters. More Details >>
- No:22852
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Indication accuracy - Ambient temperature: 25+/-5 degrees Celsius Full scale x (+/-0.3%) - Ambient temperature: 0 to 55degrees Celsius Full scale x (+/-0... More Details >>
- No:22820
- Release Date:2018/09/03 17:30
- Update:2018/09/26 16:51
- Category: MELSEC-L Series
-
Support for Q series RS-232 cable
Yes. More Details >>
- No:22803
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
MX Component's compatibility with Windows7 Embedded
MX Component does not support Windows7 Embedded. More Details >>
- No:22698
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Communication between Ethernet and FL-net
The communication between the Ethernet interface module and FL-net (OPCN-2) interface module cannot be established. More Details >>
- No:22683
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Ethernet communication after the replacement of an external device
Personal computers have different MAC addresses and an Ethernet module hold a MAC address. Hence the MAC address that the Ethernet module currently holds is ... More Details >>
- No:22665
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
MODBUS(R) interface module's involvement in master and slave stations
Intelligent function module settings allow them to be set in both master and slave stations. More Details >>
- No:22637
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to write comments of GX Works2 into the standard ROM
Switch the Target Memory to "Standard ROM" in the "Write to PLC" window. More Details >>
- No:22611
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
991-1000 of Total 1023