Built-in Ethernet function setting window of MELSEC iQ-R series CPU modules
"Module Parameter" of the CPU module is the setting window. <Setting a built-in Ethernet port> [Navigation Window]-> [Parameter]-> [CPU Modul... More Details >>
- No:22488
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:40
- Category: MELSEC iQ-R Series
-
Regarding Display Module Support
In the iQ-F series, there is no lineup of display modules. Consider usingweb server function. More Details >>
- No:40045
- Release Date:2023/08/24 15:53
- Update:2023/08/24 15:56
- Category: MELSEC iQ-F Series , CPU Module
-
SB/SW refresh device setting with CC-Link
SB/SW uses 512 points of refresh devices. More Details >>
- No:23081
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Whether or not multiple QJ72LP25-25 modules can be mounted
No, only a single QJ72LP25-25 can be mounted (and is to be mounted on the CPU slot on a main base unit). More Details >>
- No:23042
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Yes. More Details >>
- No:22998
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Difference between AJ65SBTB1-16DT1 and AJ65SBTB1-16DT2
Major differences are shown below. - AJ65SBTB1-16DT1 - Rated input current approx. 5 mA - ON voltage/ON current 15 VDC or higher/3.0 mA or higher - O... More Details >>
- No:22972
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:04
- Category: Network related products
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Simultaneous use of auto logging and backup functions
The auto logging function and backup function cannot be used simultaneously. The backup function must be used after the logging function is stopped. (A singl... More Details >>
- No:22819
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
RS-232 adapter cable disconnection prevention
Yes. More Details >>
- No:22799
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Uncheck "Check battery", an item of "Error Check", in the [PLC RAS setting] ([PLC Parameter] -> [PLC RAS setting]). More Details >>
- No:22681
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:12
- Category: MELSEC-Q Series