FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
The "S/S" terminal is used to switch the input type (sink input and source input). For the source input, connect the "S/S" terminal to the "0V" terminal, a... More Details >>
- No:22255
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
The FX5 CPU module does not support UDP broadcast communication. More Details >>
- No:22291
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Grounding FG and LG terminals of power supply module
Both of them need to be grounded. They can be shorted and grounded as one cable. More Details >>
- No:22527
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Differences between GX Works3 and GX Works2
GX Works3 provides various intuitive features such as graphic-based system configuration and an extensive module library (module label/FB) as standard. You... More Details >>
- No:22489
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:43
- Category: MELSEC iQ-R Series
-
The error code "4100" is "OPERATION ERROR". The error occurs when a number is divided by 0 (Divisor D6268 value is 0). Make modifications so that the divis... More Details >>
- No:22533
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:43
- Category: MELSEC-Q Series
-
Regarding the cause of communication error with GX Works3
From the PC's Internet Protocol Version 4 Properties, uncheck "Obtain an IP address automatically" option and set an arbitrary IP adress that does not dupli... More Details >>
- No:22319
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:38
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Difference between GX Works2 and GX Developer
Main differences between GX Works2 and GX Developer are as follows:-The functions of GX Configurator and GX Simulator are integrated as GX Works2. No additio... More Details >>
- No:22503
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Regarding how to change the IP address
The IP address can be changed from a program by using the IP address change function. The IP address change function can change the IP address, subnet mask,... More Details >>
- No:39332
- Release Date:2023/02/14 09:09
- Update:2024/08/19 09:52
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Displaying comments in GX Works2
Select [View] -> [Comment] from the menu to display comments. You can display local comments with the following procedure. (1) Select [Tool] -> [Op... More Details >>
- No:22941
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:58
- Category: Engineering Software
-
Regarding the default IP address
The default IP address (factory default value) of FX5CPU modules is 192.168.3.250. More Details >>
- No:22290
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:33
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication