FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Software required for MX Sheet
MX Component and EXCEL are required. More Details >>
- No:22646
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Those displayed under COMMENT are common comments, and others are program comments.When there are multiple programs in a project, a common comment applies to... More Details >>
- No:22540
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Difference between Q61P and Q64PN
There are differences in 5 VDC rated output current and in 5 VDC overcurrent protection.The difference in 5 VDC rated output current is as follows.- Q61P: 6 ... More Details >>
- No:22518
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Including GX Developer in GX Works2
Yes, it does.GX Developer can be installed along with the installation of GX Works2.For more details of the installation procedure, refer to GX Works2 Versio... More Details >>
- No:22506
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Regarding the Connected/Disconnected Module Detection button on FX5-CCLGN-MS
For the Connected/Disconnected Module Detection of FX5-CCLGN-MS, the network configuration of the subsequent stages can not be automatically detected unless ... More Details >>
- No:39274
- Release Date:2023/01/12 16:45
- Category: MELSEC iQ-F Series , Network/Communication
-
Limitation on the number of levels of cascade connections when QJ71E71-100 is used
If a repeater hub is used, 10BASE-T allows a maximum of four levels of cascade connections and 100BASE-TX allows a maximum of two levels of cascade connectio... More Details >>
- No:23040
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
They can be used simultaneously when I/O signals are not overlapped. The overlap of signals are checked automatically when a user select functions in the bui... More Details >>
- No:22816
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The number of modules that can be synchronized is as follows. - In single CPU system configuration: 64 modules - In multiple CPU system configuration: 57 t... More Details >>
- No:22496
- Release Date:2018/09/03 17:28
- Update:2018/09/21 17:15
- Category: MELSEC iQ-R Series
-
Whether or not totem pole output type encoders are connected
Totem pole output encoders cannot be connected to QD62.The following types of encoders can be connected.- Open collector output type encoders- CMOS level vol... More Details >>
- No:22641
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
1011-1020 of Total 1023