FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Updating to the 64-bit Windows 7 version of GX Works2
The message is displayed because the version of the CD does not support the 64-bit version. Execute the installation procedure in the condition. More Details >>
- No:22513
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:38
- Category: MELSEC-Q Series
-
Adding two channels of the RS-232C port in the FX3G series
Select the 40-point or 60-point type FX3G series main unit. In this case, two FX3G-232-BDs can be connected. When FX3G-CNV-ADP is used, anFX3U-232ADP can be ... More Details >>
- No:24926
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
-
Usage of UPS (uninterruptible power supply)
No, it cannot be used. More Details >>
- No:22831
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The fixed buffer data areas in the buffer memory are used for communication for FROM/TO instructions. The areas used in communication for FROM/TO instruction... More Details >>
- No:22656
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Setting for installing a memory cassette
When the programmable controller is powered on after a memory cassette is installed, the memory cassette is automatically recognized. After the memory casset... More Details >>
- No:24974
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
- Category: Main Unit
-
Extension blocks and units that can be used in the FX3U series
The operation is not guaranteed. Please select the extension blocks and units from FX2N series. More Details >>
- No:24935
- Release Date:2019/04/18 14:24
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
How to use built-in high-speed counters
For contacts to drive the coils of high-speed counters, use the contacts which are normally on during high-speed counting. Do not use the input (X000 to X00... More Details >>
- No:24684
- Release Date:2019/02/22 11:38
- Update:2019/02/22 15:03
- Category: MELSEC-F Series , High-Speed Counting
-
When a message indicating that "the memory space is insufficient" appears during online change
This problem occurs because the consecutive free memory space for temporarily storing the program during online change is insufficient. In this case, perform... More Details >>
- No:22722
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Copying device comments in GX Developer
Open the copy destination project in GX Developer.From the menu, select [Project] -> [Copy], specify the copy source project, and check the device comment... More Details >>
- No:22519
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
121-130 of Total 1023