Regarding Input Interrupt Delay
The following versions support the input interrupt delay function and can delay the start of execution. ・FX5U/FX5UC Ver. 1.290 or later ・FX5UJ Ver. 1.050 o... More Details >>
- No:40037
- Release Date:2023/08/24 15:43
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding communication testing of Certificate Configuration Tool for FX5-ENET
The following are possible causes for communication not being established between the Certificate Configuration Tool for FX5-ENET and FX5-ENET. (1) Connecte... More Details >>
- No:40075
- Release Date:2023/08/25 09:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding scan time adjustment for replacing the FX3 Series
You can adjust by setting the constant scan in iQ-F series. Setting procedure: Navigation window > [Parameter] > [Module model name] > [CPU Paramet... More Details >>
- No:44866
- Release Date:2025/03/18 10:24
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding KeepAlive for SLMP Communication
For TCP protocol of SLMP communication, KeepAlive is fixed and cannot be changed. In the case of UDP protocol, it is fixed to not perform a keep-alive check. More Details >>
- No:45477
- Release Date:2025/11/12 13:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
The communication can be established using the following methods. - Using the socket communication function of both CPU modules - Using the simple PLC comm... More Details >>
- No:22664
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:51
- Category: MELSEC-Q Series
-
Opening a project in an old version of GX Developer
Products earlier than version 8.58L do not support a project in which the following parameters are set. All the parameters are set to their default values be... More Details >>
- No:22666
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:53
- Category: MELSEC-Q Series
-
The numbers of POUs and steps of "Allocate Memory for 'Online Change'" in GX Works2
The maximum number of steps that an online change can process at a time is 512. More Details >>
- No:22672
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Resolution provided for L60AD4
The maximum resolution for the user range setting does not change. More Details >>
- No:22827
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:24
- Category: MELSEC-L Series
-
How to paste values in the device batch monitor window into an Excel sheet
Copy and paste operations cannot be carried out for values displayed in the device batch monitor window. To paste the values into an Excel sheet, read the d... More Details >>
- No:22888
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:54
- Category: Engineering Software