Using the email function of FX5-ENET, it is possible to send mail via a mail server. The email function is supported in the following versions. ・Hardware s... More Details >>
- No:40035
- Release Date:2023/08/24 15:40
- Update:2023/08/25 11:34
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the line tracing function
It is not supported. More Details >>
- No:39323
- Release Date:2023/02/14 09:01
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding display of FX5-ENET/IP in a Module configuration Diagram
Please update GX Works3 to the latest version. After updating, FX5-ENET/IP is displayed in the Module configuration diagram of GX Works3. Download the lates... More Details >>
- No:39303
- Release Date:2023/01/12 17:13
- Category: MELSEC iQ-F Series , Engineering Software , Network/Communication
-
Replacement of the fuse in the FX programmable controller
Customers cannot replace the fuse. For the replacement, please consult your local Mitsubishi representative. More Details >>
- No:24909
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Main Unit
-
Identifying disconnected CC-Link stations
Identify disconnected stations using either of the following methods. (1) Select [Diagnostics] -> [CC-Link Diagnostics].from the menu in GX Works2 or G... More Details >>
- No:23053
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:59
- Category: Network related products
-
PLC write not possible due to memory overload
If comments cannot be stored in the program memory, write them in the standard ROM or a memory card. Calculate the memory capacity in GX Works2 or GX Develop... More Details >>
- No:22767
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
How to increase file register capacity
In LCPU, file register capacity depends on CPU. The number of file register points cannot be increased. (A file register cannot be set on an SD memory card.)... More Details >>
- No:22766
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Unable to select [Transfer Setup]
If a circuit is being monitored or a monitor window such as the device batch monitor window is open, [Transfer Setup] on the menu is grayed out. Select [Wi... More Details >>
- No:22548
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:40
- Category: MELSEC-Q Series
-
Regarding the compatible programming tool
GX Developer/GX Works2 cannot be used. MELSEC iQ-F series only supports GX Works3. More Details >>
- No:22292
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:34
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding KeepAlive for SLMP Communication
For TCP protocol of SLMP communication, KeepAlive is fixed and cannot be changed. In the case of UDP protocol, it is fixed to not perform a keep-alive check. More Details >>