Using the inverter communication instruction in FX3G series
It can be used in the FX3G series main units with Ver. 1.10 or later. More Details >>
- No:24961
- Release Date:2019/04/23 07:17
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Externally switching the operating status of a programmable controller
On the Project view of the Navigation window, select "Parameter" → "PLC Parameter" using GX Works2 (or GX Developer). Click the "PLC System(1)" tab, and set ... More Details >>
- No:24768
- Release Date:2019/02/27 15:01
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
In order for the programmable controller to receive input pulses completely, the ON duration and OFF duration of inputs in the programmable controller requir... More Details >>
- No:24704
- Release Date:2019/02/27 09:00
- Category: MELSEC-F Series , Main Unit , High-Speed Counting
-
Difference between AJ65SBTB1-32DTE1 and AJ65SBTB1-32DT1
Major differences are shown below. - AJ65SBTB1-32DT1 - Input type positive common (sink type) - Rated input current approx. 5 mA - ON voltage/ON curr... More Details >>
- No:23022
- Release Date:2018/09/03 17:31
- Update:2018/09/26 09:52
- Category: Network related products
-
How refresh devices for CC-Link remote inputs and outputs are assigned
The refresh device setting of the CC-Link parameter assigns any devices to the I/O numbers greater than those assigned to the modules on the same base unit. ... More Details >>
- No:22968
- Release Date:2018/09/03 17:31
- Category: Network related products
-
The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is that... More Details >>
- No:22797
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
SD1282 of LCPU with built-in Ethernet port
The bits 0 to F of the special register SD1282 (Open completion signal) correspond to the connection numbers 1 to 16. When the open processing is completed, ... More Details >>
- No:22751
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Inputting device comments in GX Works2
Select [Tool] -> [Options] -> [Program Editor] -> "Ladder/SFC"-> "Comment" and change "Reference/Reflection Target for Device Comment" from "Glob... More Details >>
- No:22559
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Unable to select [Transfer Setup]
If a circuit is being monitored or a monitor window such as the device batch monitor window is open, [Transfer Setup] on the menu is grayed out. Select [Wi... More Details >>
- No:22548
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:40
- Category: MELSEC-Q Series
-
Changing to the monitor write mode automatically changes the online change setting in Options to "Write during RUN (while PLC is running)".With returning to ... More Details >>
- No:22541
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series