Necessity of terminating resistors in CC-Link communication
No, it is unnecessary. Terminating resistors are only required at both ends of the network. More Details >>
- No:22966
- Release Date:2018/09/03 17:31
- Category: Network related products
-
There are three types of parameters in GX Works3; "System parameter", "CPU parameter", and "Module parameter". You can set the following items with each par... More Details >>
- No:22483
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:08
- Category: MELSEC iQ-R Series
-
You can use the MELSEC iQ-R series inter-module synchronization function together with the CC-Link IE Field Network synchronous communication function.With ... More Details >>
- No:22462
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:51
- Category: MELSEC iQ-R Series
-
Regarding I/O assignment on the module configuration diagram of GX Works3
While the module configuration window is being displayed, the I/O assignment can be checked by selecting the following options from the menu bar: [Edit]→[X... More Details >>
- No:22307
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:25
- Category: CPU Module , I/O Module , Engineering Software
-
Ethernet-connectable modules in MELSEC-F
The FX3U-ENET-L and FX3U-ENET-ADP are Ethernet-connectable. The FX3U-ENET-L can be used with the FX3U and FX3UC series (both Ver. 2.21 or later). The FX3U-... More Details >>
- No:22270
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Battery replacement during power-on
Replacethe battery when the programmable controller is powered off. For example, forthe FX3U/FX3UC series, data will be held for about 20 seconds after be... More Details >>
- No:22257
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:54
- Category: MELSEC-F Series , Main Unit , Accessories
-
Regarding automatic transfer of Data Logging Files
Data logging file transfer (FTP server auto transfer) is supported with the following firmware versions. ・FX5U/FX5UC CPU Module Ver. 1.300 or later ・FX5U... More Details >>
- No:44334
- Release Date:2024/03/20 13:30
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding handling multiple executions of ADPRW Instructions
When multiple ADPRW instructions are simultaneously executed, communication by the ADPRW command that was executed earlier is completed and communication by ... More Details >>
- No:39354
- Release Date:2023/02/15 10:17
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
I cannot convert a circuit created with GX Developer.
When the conversion is executed, online change is automatically executed.When the online change at the upper right section of the setting in "Options" of "To... More Details >>
- No:22958
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
The error code "2400" is "FILE SET ERROR". This error may be caused when the file specified with a parameter does not exist. The individual information param... More Details >>
- No:22729
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series