FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Regarding reading Sample Comments for Expansion Adapters
You cannot. The expansion adapters does not support reading sample comments. More Details >>
- No:39352
- Release Date:2023/02/15 10:16
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the number of FX5-4A-ADP connections
Up to 4 FX5-4A-ADPs can be connected to an FX5U/FX5UC/FX5S CPU module. To connect 3 or more FX5-4A-ADPs, the FX5-4A-ADP must have a serial number S/N: 224... More Details >>
- No:39348
- Release Date:2023/02/15 10:16
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
It is not possible to convert to GX Works2 format. More Details >>
- No:39326
- Release Date:2023/02/14 09:03
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the difference between digital output values and digital operation values
The digital output value is a digital value obtained by performing sampling processing or various average processing on the A/D converted digital value. Dig... More Details >>
- No:39307
- Release Date:2023/02/13 16:43
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
AC input type main unit in the FX3 series
FX3U-32MR/UA1 and FX3U-64MR/UA1 are AC input types. More Details >>
- No:24991
- Release Date:2019/04/23 10:37
- Category: MELSEC-F Series , Main Unit
-
Connection of the FX3GC series and FX3U-ENET-ADP
Since the FX3U-ENET-ADP can be connected directly to the FX3GC series, optional equipment is not required. * When the FX3U-ENET-ADP is used with other spe... More Details >>
- No:24976
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Assignment of direction signals during positioning
Any number can be assigned. More Details >>
- No:24975
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Positioning Control
-
Connection of the FX3G series and the FX3U-ENET-ADP
AnFX3G-CNV-ADP is required. * When the FX3U-ENET-ADP is used with other special adapters, connect the FX3U-ENET-ADP at the last stage (left end). More Details >>
- No:24951
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit
-
Assignment of remote input device and remote output device of FX3U-16CCL-M
The remote input device and the remote output device cannot be assigned in network parameters. To assign them, create a program for updating data. For de... More Details >>
- No:24792
- Release Date:2019/02/28 09:08
- Category: MELSEC-F Series , Engineering Software , Network/Communication
201-210 of Total 1010