FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
To assure 32-bit data, "Network Range Assignment" of the control station must satisfy the following conditions.(1) The start device No. of LB is a multiple o... More Details >>
- No:23052
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Reading a project in another format
To open a project created with GX Developer, select [Project]-> [Import file]-> [Import from xxxx format file] from the menu in GX Works2. More Details >>
- No:22952
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:56
- Category: Engineering Software
-
Operation error at the execution of a BIN instruction
Keep SM722 ON or correct the program so that any one of the ten numbers 0 to 9 is stored in each digit of the source data.An operation error occurs when data... More Details >>
- No:22635
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Is the version of MX Component compatible with Windows 7? Update the software to the version compatible with Windows 7 and then update the driver. For the ... More Details >>
- No:22569
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:50
- Category: MELSEC-Q Series
-
Usage of PIDCONT instruction in process CPU
No. More Details >>
- No:22536
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Regarding program execution using SD Memory Cards
It's possible. Use the boot operation function of the SD memory card. *To use the boot operation function with the FX5S CPU module, you need to install an a... More Details >>
- No:39311
- Release Date:2023/02/14 08:54
- Category: MELSEC iQ-F Series , Option , CPU Module
-
Number of FX3U-64CCL interface blocks that can be added to a main unit
One FX3U-64CCL can be added. More Details >>
- No:24962
- Release Date:2019/04/23 07:17
- Category: MELSEC-F Series , Network/Communication
-
Battery consumption while the programmable controller is powered on
A battery is consumed regardless of the on/off state ofthe programmable controller. Refer to the User's Manual (Hardware Edition) for the module used, and r... More Details >>
- No:24687
- Release Date:2019/02/22 11:44
- Update:2019/02/22 15:22
- Category: MELSEC-F Series , Main Unit , Accessories
-
Difference in specifications between CC-Link versions
Ver.1.10 is a standard where CC-Link station-to-station cable length restriction in Ver. 1.00 has been removed, and the length of all station-to-station cabl... More Details >>
- No:22975
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Necessity for GX Configurator-SC
The serial communication modules do not require GX Configurator-SC. However, we recommend GX Configurator-SC as it reduces man-hours. (1) The predefined ... More Details >>
- No:22905
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:33
- Category: Engineering Software
201-210 of Total 1023