Assignment of direction signals during positioning
Any number can be assigned. More Details >>
- No:24975
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Positioning Control
-
Power supply cable of the input extension blocks for the connector type programmable controllers
Forthe first input extension block connecting to a main unit, use the FX2NC-100BPCB power supply cable provided with the main unit, and supply power from a 2... More Details >>
- No:24911
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Regarding the processing specification of the basic operation instruction(LD).
The execution time of the basic opeartion instruction (LD) of the FX5U/FX5UC/FX5UJ CPU module is 34 ns. *For firmware Ver.1.100 or above, this specification ... More Details >>
- No:22287
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding replacing FLT Instructions
For the iQ-F series, use the following instructions. For signed 16 bit integers, use the INT2FLT instruction. For unsigned 16 bit integers, use the UINT2FL... More Details >>
- No:45479
- Release Date:2025/11/12 13:54
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding changing the current address (user unit, pulse unit)
It can be changed. It is now possible to write to the address (user unit, pulse unit) by the DHCMOV command. However, writing is disabled during positioning... More Details >>
- No:39356
- Release Date:2023/02/15 13:03
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding the supported version of the simple CPU communication function
For FX5U/FX5UC CPU module, firmware version 1.110 or later is supported. For the FX5UJ/FX5S CPU module, it is compatible from the first one. More Details >>
- No:39316
- Release Date:2023/02/14 08:56
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Parameter setting of the FX3U-16CCL-M
The parameters can be set by using network parameters of GX Works2 (Ver1.73B or later). (FX3U/3UC: Ver3.10 or later) More Details >>
- No:25013
- Release Date:2019/04/23 11:16
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
One FX3U-ENET-ADP can be connected at the last stage (left end) of adapters for the FX3UC series. *The FX3U-ENET-ADP is a communication special adapter and ... More Details >>
- No:24932
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Main Unit
-
Overwriting a current value with the high-speed counter comparison instruction
The output contact is activated according to the change of the current value register along with the counting input. Therefore, the value changed by executin... More Details >>
- No:24931
- Release Date:2019/04/17 11:43
- Category: MELSEC-F Series , Main Unit
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
- Category: MELSEC-F Series , Engineering Software , Main Unit