Use a T-branch repeater module instead of a terminal block. More Details >>
- No:23086
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How to use built-in high-speed counters
For contacts to drive the coils of high-speed counters, use the contacts which are normally on during high-speed counting. Do not use the input (X000 to X00... More Details >>
- No:24684
- Release Date:2019/02/22 11:38
- Update:2019/02/22 15:03
- Category: MELSEC-F Series , High-Speed Counting
-
Battery consumption while the programmable controller is powered on
A battery is consumed regardless of the on/off state ofthe programmable controller. Refer to the User's Manual (Hardware Edition) for the module used, and r... More Details >>
- No:24687
- Release Date:2019/02/22 11:44
- Update:2019/02/22 15:22
- Category: MELSEC-F Series , Main Unit , Accessories
-
Clock function accuracy of the MELSEC-F series
The accuracy is within ±45 seconds/month (ambient temperature: 25ºC). More Details >>
- No:24778
- Release Date:2019/02/27 15:57
- Category: MELSEC-F Series , Main Unit
-
Connecting local stations to the FX3U-16CCL-M
No, local stations cannot be connected to the FX3U-16CCL-M. Remote I/O stations, remote device stations, and intelligent device stations can be connected to... More Details >>
- No:24791
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Network/Communication
-
The FX3U-ENET-L does not support the DHCP function. Set the fixed IP address using FX Configurator-EN-L. (FX Configurator-EN-L can be downloaded from Mitsubi... More Details >>
- No:24869
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series
-
Setting of the FX3U-ENET-ADP Ethernet communication special adapter
GX Works2 with Ver. 1.90U or later can be used for the setting of the FX3U-ENET-ADP. More Details >>
- No:24875
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Network/Communication
-
Use of latched (battery backed) type auxiliary relay
If the OUT instruction using a latched (battery backed) type auxiliary relay number exists in a sequence program, the information held may be overwritten by ... More Details >>
- No:24877
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Main Unit
-
Positioning blocks/module that can be connected with a manual pulse generator
The FX3U-20SSC-H (differential line driver), FX2N-10PG (differential line driver or open collector: only 5 V type), and FX2N-10GM/FX2N-20GM (open collector) ... More Details >>
- No:24886
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Positioning Control
-
Terminal layout of the FX3U-1PG and FX2N-1PG pulse output blocks
Yes, they have the same terminal layout. More Details >>
- No:24900
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Positioning Control