FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Opening SFC programs in GX Works2
To open a GX Developer project, select [Project] -> [Open Other Data] -> [Open Other Project] from the menu of GX Works2. More Details >>
- No:22878
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Communication setting methods when the FX3U-232-BD is used
The non-protocol communication can be set by the following two methods: (1) setting parameters using a programming tool, such as GX Works2, or (2) writing da... More Details >>
- No:24773
- Release Date:2019/02/27 15:24
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
Regarding EtherNet/IP Communications
The built-in Ethernet port on the FX5 CPU module does not support EtherNet/IP communication. Use FX5-ENET/IP. More Details >>
- No:39319
- Release Date:2023/02/14 08:57
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding comparison of Strings
Use the string comparison instructions LD$□, AND$□, OR$□. □contains =, <>, >, < =, <, > =. More Details >>
- No:39355
- Release Date:2023/02/15 13:03
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding changing the current address (user unit, pulse unit)
It can be changed. It is now possible to write to the address (user unit, pulse unit) by the DHCMOV command. However, writing is disabled during positioning... More Details >>
- No:39356
- Release Date:2023/02/15 13:03
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding the FX5UC CPU module/Intelligent Function module Power Cable
The model name of the power cable is FX2NC-100MPCB. It is included with the FX5UC CPU module and intelligent function modules that require power from the pow... More Details >>
- No:40021
- Release Date:2023/08/24 14:31
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication , Motion/Positioning , Analog
-
EN (enable input) ・・・ This is the execution condition of the function. The function with EN is executed only if the execution condition of EN... More Details >>
- No:40024
- Release Date:2023/08/24 14:35
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding instructions for converting constants from decimal to hexadecimal
Decimal numbers of up to 4 digits can be converted to hexadecimal numbers using the BCD(P) instruction, and decimal numbers of up to 8 digits can be converte... More Details >>
- No:44352
- Release Date:2024/03/27 15:43
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding swapping upper and lower bytes of string data
You can use the SWAP (P) command to swap the upper and lower bytes of the specified device. More Details >>
- No:44361
- Release Date:2024/03/27 15:55
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
261-270 of Total 1023