An error occurs and CPU will stop. Install the END cover and reset the CPU module. More Details >>
- No:22817
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Battery install position in LCPU
Open the cover at the bottom of the CPU module and install the battery. More Details >>
- No:22821
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
GX Developer's compatibility with QnUDVCPU
GX Developer does not support QnUDVCPU. Please use GX Works2 instead. More Details >>
- No:22885
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Dragging and dropping function blocks in a structured project
Function blocks can be dragged and dropped into the program main body of the program block, and become available in the program. More Details >>
- No:22910
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Resistor value for CC-Link cables
The value depends on the type of cable in use. - Ver.1.10-compatible CC-Link dedicated cables: 110 ohm, 1/2W - CC-Link dedicated cables (Version 1.00): 110... More Details >>
- No:22983
- Release Date:2018/09/03 17:31
- Update:2018/10/03 14:42
- Category: Network related products
-
PLC parameter setting for QJ61BT11N
If the Network Parameter is used, CC-Link communication does not need the Select setting in the I/O assignment setting of the PLC parameter.If the parameter ... More Details >>
- No:23002
- Release Date:2018/09/03 17:31
- Category: Network related products
-
For CPU modules with 8192 I/O device points (X/Y0 to 1FFF), X/Y1000 and greater can be set as refresh devices. More Details >>
- No:23014
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Receiving data when no receive complete code is designated (QJ71C24N)
Data are received on a received data count basis. If there is no receive complete code and variable length data is received, the data is received at every no... More Details >>
- No:23038
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Order in which a CC-Link master module and slave stations are connected
There is no restriction on the positions of a master station and slave stations where they are connected. (Stations are not required to be connected in order... More Details >>
- No:23041
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Link data from communication error stations in a CC-Link network
The remote input RX of the master station and the remote input RX and remote output RY of local stations clear/hold the data from an error station according ... More Details >>
- No:23057
- Release Date:2018/09/03 17:31
- Category: Network related products
301-310 of Total 1023