Identifying an SFC program block in execution
Specify a block in the cross reference list and search it. (For block 1, search BL1, for example.) More Details >>
- No:22907
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Print function of GX Developer
The Print Preview window of GX Developer is a function for checking a print image, made to a specification that allows display of only the first page. A page... More Details >>
- No:22870
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
MX Component Version 4's compatibility with Visual Studio 2010
The initial version and subsequent versions of MX Component Version 4 support Visual Basic and Visual C++ of Visual Studio 2010. More Details >>
- No:22842
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
The minimum input response times are different. The minimum input response time is 100 microseconds for standard inputs, and 10 microseconds for high-speed i... More Details >>
- No:22804
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Support for Q series RS-232 cable
Yes. More Details >>
- No:22803
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
When the block number of the file register (R) is saved and stored, the overhead time becomes 35.9 [us]. When the number of the file register is not saved o... More Details >>
- No:22465
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:57
- Category: MELSEC iQ-R Series
-
Restriction on the use of CPU when branch module and extension module are used
Use L series CPU modules whose first 5 digits of the serial number are "13072" or later. More Details >>
- No:22800
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Refer to the following manual. MELSEC-L CPU Module User's Manual (Function Explanation, Program Fundamentals) Appendix 1 More Details >>
- No:22798
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The contents of the standard RAM and latch devices are not erased if the battery replacement is completed within three minutes, which is the backup power tim... More Details >>
- No:22733
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Connection of the FX3GC series and FX3U-ENET-ADP
Since the FX3U-ENET-ADP can be connected directly to the FX3GC series, optional equipment is not required. * When the FX3U-ENET-ADP is used with other spe... More Details >>
- No:24976
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Network/Communication