Target address change during the positioning operation in the FX3U-1PG
Yes, it is possible. Set a new value for the target address to the target address change value (BFM#54, #53) during the positioning operation. * The targ... More Details >>
- No:24986
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
Cable provided with the FX2N series extension unit
It is available as a repair part. Please consult with localMitsubishi Electric representative. More Details >>
- No:24916
- Release Date:2019/04/17 11:40
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Latched (battery backed) area in the data register (D) of the FX3G/FX3GC series
D128 to D1099 are the latched device area. D1100 to D7999 can be changed to latched (battery backed) type devices by installing an optional battery and setti... More Details >>
- No:24901
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Main Unit
-
Battery consumption while the programmable controller is powered on
A battery is consumed regardless of the on/off state ofthe programmable controller. Refer to the User's Manual (Hardware Edition) for the module used, and r... More Details >>
- No:24687
- Release Date:2019/02/22 11:44
- Update:2019/02/22 15:22
- Category: MELSEC-F Series , Main Unit , Accessories
-
The number of FB definitions created in a project has no limitation. More Details >>
- No:22900
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Using send FBs/receive FBs simultaneously
If multiple send FBs/receive FBs are simultaneously executed, the FBs do not function properly.When there are multiple send FBs, do not execute two or more s... More Details >>
- No:22893
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
LCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices.- Protocol: "UDP"- Open System: "MELSOFT connection" More Details >>
- No:22739
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Error code "2200" in the High-Performance model QCPU
The error code "2200" is "MISSING PARA.". It may be determined as the cause of the error that there is no parameter file in the parameter-valid drive that h... More Details >>
- No:22699
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:24
- Category: MELSEC-Q Series
-
Setting of "Target MODBUS(R) device head number"
Set "(Last five digits of actual device number) - 1" for the Target MODBUS(R) device head number.Example) For the holding register 400018, set "17". More Details >>
- No:22682
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Memory allocation for online change in GX Developer
Select [Online] -> [Write to PLC] on the menu of GX Developer, open the [File selection] tab, and press "Param + Prog" button. Then open the [Program] ta... More Details >>
- No:22547
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:09
- Category: MELSEC-Q Series
301-310 of Total 1023