FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
The FX2N-16CCL-M cannot be set as the master station in the parameter setting. Use the FROM/TO instructions and setin the program. More Details >>
- No:25001
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Network/Communication
-
Setting for installing a memory cassette
When the programmable controller is powered on after a memory cassette is installed, the memory cassette is automatically recognized. After the memory casset... More Details >>
- No:24974
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Adding FX3U series expansion boards to an FX3UC series main unit
FX3U series expansion boards can be added to FX3UC-32MT-LT and FX3UC-32MT-LT2. More Details >>
- No:24963
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Main Unit
-
Drive products (servo amplifiers) that can be connected to the FX3U-1PG pulse output block
Servo amplifiers, such as MR-J4-□A and MR-JN-□A, that support pulse train input can be connected. For connectable drive products, such as servo amplifiers, ... More Details >>
- No:24940
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
For output terminals of a programmable controller, one common terminal is used for 1, 2, 4, or 8 output points. Each common line is assigned with a different... More Details >>
- No:24780
- Release Date:2019/02/27 15:58
- Category: MELSEC-F Series , Main Unit
-
Checking the amount of free space of the memory in GX Developer/GX Works2
Select [Tool] -> [Confirm Memory Size] to check the amount. More Details >>
- No:22851
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Error code "2200" in the High-Performance model QCPU
The error code "2200" is "MISSING PARA.". It may be determined as the cause of the error that there is no parameter file in the parameter-valid drive that h... More Details >>
- No:22699
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:24
- Category: MELSEC-Q Series
-
Difference between SM0 and SM1
SM0 turns ON when self-diagnostic checks detect an error or when an annunciator turns ON.SM1 turns ON when self-diagnostic checks detect an error. More Details >>
- No:22632
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to copy comments from GX Developer to GX Works2
Launch GX Works2, select [Project] -> [Open Other Project], and read the data created with GX Developer. Copy the comment from the list of device comme... More Details >>
- No:22526
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:32
- Category: MELSEC-Q Series
-
GX Works3 is compatible with the following OSs. (As of Sep,2018) - Microsoft Windows 10 - Microsoft Windows 8.1 - Microsoft Windows 8 - Microsoft Windo... More Details >>
- No:22473
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:38
- Category: MELSEC iQ-R Series
301-310 of Total 1010