AC input type main unit in the FX3 series
FX3U-32MR/UA1 and FX3U-64MR/UA1 are AC input types. More Details >>
- No:24991
- Release Date:2019/04/23 10:37
- Category: MELSEC-F Series , Main Unit
-
Connection of a memory cassette and a display module to the FX3G series main unit
For the 14/24-point type FX3G series main unit, they cannot be connected together. For the 40/60-point type FX3G series main unit, they canbe connected toget... More Details >>
- No:24978
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Pulse output type of the FX3U-1PG pulse output block
It is transistor output. Transistor output specifications are as follows. ・ Rated load voltage 5 to 24 V DC ・ Maximum load current 20 mA or lower More Details >>
- No:24972
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control
-
Ver2.00 or later is applicable. (GX Works2 with Ver. 1.87R or later is applicable.) The version of main units can be checked with the last three digits of t... More Details >>
- No:24922
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Main Unit
-
Differences in the specifications between the programmable controllers used in Japan and overseas.
The input signal forms are different. All the programmable controllers for the domestic market other than the FX3G/FX3U series are the sink input. The progra... More Details >>
- No:24913
- Release Date:2019/04/17 11:39
- Category: MELSEC-F Series , Main Unit
-
Replacement of the fuse in the FX programmable controller
Customers cannot replace the fuse. For the replacement, please consult your local Mitsubishi representative. More Details >>
- No:24909
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Main Unit
-
Models from the FX programmable controllers that support the extended register (R)
The following models from the FX3 series support the extended register (R). FX3U/FX3UC series: R0-R32767, FX3G series: R0-R23999 More Details >>
- No:24904
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Main Unit
-
Modules that support differential line driver outputs
The FX3U-2HSY-ADP, FX2N-10PG support differential line driver outputs. More Details >>
- No:24691
- Release Date:2019/02/27 08:56
- Update:2023/02/15 13:09
- Category: MELSEC-F Series , Positioning Control
-
Identifying disconnected CC-Link stations
Identify disconnected stations using either of the following methods. (1) Select [Diagnostics] -> [CC-Link Diagnostics].from the menu in GX Works2 or G... More Details >>
- No:23053
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:59
- Category: Network related products
-
Using a FROM/TO instruction after AJ71UC24 is replaced with QJ71C24N
I/O signals and buffer memory addresses need to be changed but data communications can be conducted using a FROM/TO instruction and X/Y signals. More Details >>
- No:23017
- Release Date:2018/09/03 17:31
- Category: Network related products