FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Unit of the receive data length used by the QJ71C24N series pre-defined protocol support function
The receive data length of the variable is specified in bytes. More Details >>
- No:23037
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Yes, there is. T256 to T319 can be used for the1 ms timer, and T246 to T249 can be used for the 1 ms retentive timer. More Details >>
- No:24680
- Release Date:2019/02/22 11:39
- Update:2019/02/22 14:03
- Category: MELSEC-F Series , Main Unit
-
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>
- No:24943
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
GX Works3 is compatible with the following OSs. (As of Sep,2018) - Microsoft Windows 10 - Microsoft Windows 8.1 - Microsoft Windows 8 - Microsoft Windo... More Details >>
- No:22473
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:38
- Category: MELSEC iQ-R Series
-
How to read comments in the standard ROM with GX Works2
Select [Target Memory] -> [Standard ROM] in the Read from PLC window. More Details >>
- No:22673
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:05
- Category: MELSEC-Q Series
-
Boot file setting of the QnUDVCPU
No. You cannot use an SRAM card, ATA card, or Flash card. Specify an SD memory card as the transfer source (boot source). More Details >>
- No:22714
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Duplicated coil errors that can be checked with GX Works2
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22932
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Ethernet cables for the CC-Link IE Field Network
General-purpose Ethernet cables that meet the 1000BASE-T standard (category 5e or higher) can be used. We recommend double shielded cables. Recommended pro... More Details >>
- No:22989
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:47
- Category: Network related products
-
Setting required to skip CC-Link slave station numbers
A CC-Link slave station number can be skipped by assigning the skipped number to a reserved station. A reserved station is counted as one of all the connecte... More Details >>
- No:23029
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Pulse output system of the FX3U-1PG pulse output block
Forward (FP) and reverse (RP) pulse or pulse (PLS) with direction (DIR) can be selected. More Details >>
- No:24957
- Release Date:2019/04/18 14:28
- Category: MELSEC-F Series , Positioning Control
331-340 of Total 1010