FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Unit of the receive data length used by the QJ71C24N series pre-defined protocol support function
The receive data length of the variable is specified in bytes. More Details >>
- No:23037
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Setting required to skip CC-Link slave station numbers
A CC-Link slave station number can be skipped by assigning the skipped number to a reserved station. A reserved station is counted as one of all the connecte... More Details >>
- No:23029
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Transient transmission of the CC-Link IE Controller
Transient transmission is a function that allows communication with programmable controllers in other stations. Communication with programmable controllers i... More Details >>
- No:23016
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link master modules' start I/O No. and refresh devices RX/RY
The I/O numbers used for I/O modules and intelligent function modules cannot be used as refresh targets for RX/RY. Use the I/O numbers greater than those use... More Details >>
- No:22997
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How to set CC-Link reserved stations
- If the Network Parameter is used Make "Station Information Setting". - If the parameter is set using a dedicated instruction Set the control data of... More Details >>
- No:22996
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:41
- Category: Network related products
-
Difference between CC-Link reserved stations and invalid stations
- Reserved station Reserved stations are not actually connected to the network (but will be connected in the future) but do not appear as data link error... More Details >>
- No:22993
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:37
- Category: Network related products
-
Mixing the CC-Link IE Field Network with general LAN communication
Mixed communication with the same hub cannot be established. Establish the CC-Link IE Field Network and general LAN communication separately. More Details >>
- No:22988
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:48
- Category: Network related products
-
RS-485 connection between QJ71C24N and an external device
Short between SDA and RDA and between SDB and RDB, and then connect them to + (Data-A) and - (Data-B) on the external device. More Details >>
- No:22986
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Terminating resistors for QJ71C24N
A terminating resistor must be connected to the interface in order to reduce signal reflections thus preventing the signal instabilities. More Details >>
- No:22982
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How refresh devices for CC-Link remote inputs and outputs are assigned
The refresh device setting of the CC-Link parameter assigns any devices to the I/O numbers greater than those assigned to the modules on the same base unit. ... More Details >>
- No:22968
- Release Date:2018/09/03 17:31
- Category: Network related products
361-370 of Total 1010