FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Setting for sequentially inputting device comments in GX Works2
Select [Tool]-> [Options]-> [Program Editor] -> [Ladder/SFC] -> [Enter ladder] from the menu, and set [Enter label comment and device comment]... More Details >>
- No:22938
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:54
- Category: Engineering Software
-
CC-Link slave station's flashing L.ERR LED
If the L.ERR LED flashes at irregular intervals, it may indicate that no terminating resistor has been connected or the communication is instable due to the ... More Details >>
- No:23001
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Limitation on the number of levels of cascade connections when QJ71E71-100 is used
If a repeater hub is used, 10BASE-T allows a maximum of four levels of cascade connections and 100BASE-TX allows a maximum of two levels of cascade connectio... More Details >>
- No:23040
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Precaution about MELSECNET/H connection (2)
- Set the network module mounted in system A to station number 0 (multiplexed remote master station). Set the network module mounted in system B to any sta... More Details >>
- No:23054
- Release Date:2018/09/03 17:31
- Update:2018/09/26 11:00
- Category: Network related products
-
Number of occupied points of special function devices
Each special function unit/block has 8 occupied points, except for some special function devices. These 8 points do not occupy 8 points of the actual I/O n... More Details >>
- No:24873
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Main Unit
-
One FX3U-ENET-ADP can be connected at the last stage (left end) of adapters for the FX3UC series. *The FX3U-ENET-ADP is a communication special adapter and ... More Details >>
- No:24932
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Main Unit
-
Adding FX3U series expansion boards to an FX3UC series main unit
FX3U series expansion boards can be added to FX3UC-32MT-LT and FX3UC-32MT-LT2. More Details >>
- No:24963
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Main Unit
-
Connection of a totem pole output encoder
The totem pole output encoder cannot be connected to the FX2NC-1HC/FX2N-1HC/ FX3U-2HC. The connectable encoders are as follows. ・ Open collector output typ... More Details >>
- No:25010
- Release Date:2019/04/23 11:12
- Category: MELSEC-F Series , High-Speed Counting
-
Regarding performing Data Logging with Special Relays
It's possible. Using special relays, it is possible to perform data logging from a program. For details, see the manual below. MELSEC iQ-F FX5 User's Manu... More Details >>
- No:39327
- Release Date:2023/02/14 09:05
- Category: MELSEC iQ-F Series , CPU Module
-
Copying programs when replacing the CPU module
Programs and parameters can be copied using the memory copy function.There are the following two methods of executing the memory copy function.- Using the me... More Details >>
- No:22644
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
371-380 of Total 1010