Buffer memory addresses of CC-Link modules
If the remote net Ver.1 mode is used, each station number is given fixed buffer memory addresses.If the remote net Ver.2 mode is used, different buffer memor... More Details >>
- No:22992
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How to make the expanded cyclic setting for CC-Link local stations
Make the expanded cyclic setting for a CC-Link local station using the programming tool, GX Developer or GX Works2. Follow the procedure below. (1) Set th... More Details >>
- No:23030
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:17
- Category: Network related products
-
Duplication error in a CC-Link master station
Possible causes are as follows.(1) Another master station exists on the same line.(2) Noise is detected on the line at power on. More Details >>
- No:23044
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Do not use vacant terminals. More Details >>
- No:25003
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Regarding how to start positioning
In the case of positioning control and OPR control, there are three ways to start positioning: (1)[cd. 184] Turn on the positioning start signal. (2)Exec... More Details >>
- No:39360
- Release Date:2023/01/12 17:19
- Category: MELSEC iQ-F Series , Motion/Positioning
-
How to display the network parameter setting window with GX Works3
"Network Parameter" in GX Works2 is "Module Parameter" of a "network module" in GX Works3. Click the items in the following order to display the setting win... More Details >>
- No:22485
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:55
- Category: MELSEC iQ-R Series
-
You can synchronize the fixed scan communication cycle of the multiple CPU system function with the inter-module synchronization cycle of the inter-module s... More Details >>
- No:22494
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:12
- Category: MELSEC iQ-R Series
-
CPU modules supporting the serial communication function
CPU modules supporting the serial communication function are as follows. - Q00UJCPU,Q00UCPU,Q01UCPU - Q02UCPU 10102 or later (with GX Works2 1.15R or l... More Details >>
- No:22530
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:37
- Category: MELSEC-Q Series
-
Resolution provided for Q64AD/Q68ADV/Q68ADI
The maximum resolution for the user range setting does not change. More Details >>
- No:22591
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:01
- Category: MELSEC-Q Series
-
QnA-compatible 3E frame command (0406) for the built-in Ethernet port QCPU
The built-in Ethernet port QCPU is not compatible with a multiple-block batch read command (0406) of the MC protocol. Executable commands are the following.... More Details >>
- No:22608
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:09
- Category: MELSEC-Q Series