Regarding how to update the firmware of the FX5 CPU module
FX5U/FX5UC/FX5UJ CPU modules cannot perform firmware update using GX Works3. Use the SD memory card to update the firmware. However, the FX5S CPU module sup... More Details >>
- No:39325
- Release Date:2023/02/14 09:03
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
When the message "An unusable COM port was specified" is displayed
RS-232 is selected as PC side I/F in Transfer Setup of GX Developer or GX Works2.Change the setting in PC side I/F to USB. More Details >>
- No:22517
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Regarding I/O assignment on the module configuration diagram of GX Works3
While the module configuration window is being displayed, the I/O assignment can be checked by selecting the following options from the menu bar: [Edit]→[X... More Details >>
- No:22307
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:25
- Category: CPU Module , I/O Module , Engineering Software
-
Yes. A USB driver needs to be installed.For the installation procedure, refer to the following manual. - GX Developer Version 8 Operating Manual (Startup) More Details >>
- No:22504
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:10
- Category: MELSEC-Q Series
-
The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is th... More Details >>
- No:22535
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:46
- Category: MELSEC-Q Series
-
Changing the display language of device comments with GX Works3
In the multiple comments display setting, you can set a comment title of the device comments to be set. <Displaying the multiple comments display setti... More Details >>
- No:22460
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:46
- Category: MELSEC iQ-R Series
-
Regarding the latch settings of data register
It is necessary to set the latch range from the following GX Works3 parameters: [Navigation Window] -> [CPU Parameters] -> [Device/Memory Settings] -&... More Details >>
- No:22329
- Release Date:2018/08/30 13:55
- Update:2024/11/11 13:49
- Category: CPU Module , Engineering Software
-
Uninstalling GX Works2 before the installation of GX Works3
You do not have to uninstall GX Works2 before installing GX Works3. You can install GX Works3 into your computer where GX Works2 has already been installed. More Details >>
- No:22464
- Release Date:2018/09/03 17:28
- Update:2018/09/18 16:20
- Category: MELSEC iQ-R Series
-
Latch (backup) areas in the data register (D) and extended register (R) of the FX3U/FX3UC series
D200 to D7999 and R0 to R32767 can be latched. D200 to D511 can be set as non-latch areas in parameters. For details on the parameter setting, refer to the... More Details >>
- No:24699
- Release Date:2019/02/27 08:58
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
How to check the version of the MELSEC-F series
To check the version of the MELSEC-F series, connect GX Works2 (personal computer) or HPP to a programmable controller, and monitor the data in D8001. The l... More Details >>
- No:24772
- Release Date:2019/02/27 15:22
- Category: MELSEC-F Series , Engineering Software , Main Unit