FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Continuous executions of protocols by the QJ71C24N series CPRTCL instruction
One CPRTCL instruction can execute a maximum of eight protocols. More Details >>
- No:23050
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Relation between CC-Link terminals and signal lines
The following shows the relations between CC-Link terminals and signal lines. - DA : Blue -DB: White -DG: Yellow More Details >>
- No:23077
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:11
- Category: Network related products
-
Connection of expansion boards and a display module to FX3G series main unit
They can be used together. * 14/24-point type FX3G series main unit ・ An expansion board can be connected to BD1 (1st position) and a display module can be... More Details >>
- No:24985
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Main Unit
-
AC input type main unit in the FX3 series
FX3U-32MR/UA1 and FX3U-64MR/UA1 are AC input types. More Details >>
- No:24991
- Release Date:2019/04/23 10:37
- Category: MELSEC-F Series , Main Unit
-
CC-Link version of FX2N-16CCL-M
The CC-Link version ofFX2N-16CCL-M is Ver.1.10. More Details >>
- No:24992
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Network/Communication
-
Remote maintenance can be performed by writing a program to a memory cassette and sending the program or by using a personal computer (GX Developer). With a ... More Details >>
- No:24998
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Main Unit
-
Regarding the effect of battery voltage drop on logging function
Since the battery retains clock data even after power failure, the time of logging data may change. More Details >>
- No:39310
- Release Date:2023/01/12 16:53
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding FX5S CPU module Terminal Block Removal
You can't put it on or take it off. The terminal block of the FX5S CPU module is a non-removable terminal block. More Details >>
- No:39334
- Release Date:2023/02/14 09:10
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding terminal block reuse
Terminal blocks can not be reused. Please rewire it. More Details >>
- No:39365
- Release Date:2023/02/15 13:06
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Data Collection for Device Comments
It is not possible to collect device comments. More Details >>
- No:40030
- Release Date:2023/08/24 14:40
- Category: MELSEC iQ-F Series , CPU Module
401-410 of Total 1023