FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Pulse width with which the QX42 recognizes all pulses
Maximum scan time (10 ms) + Response time (10 ms) = Pulse width with which the module recognizes all pulses (20 ms) More Details >>
- No:22720
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
QnA-compatible 3E frame command for built-in Ethernet port in LCPU
The built-in Ethernet port in the L series CPU is not compatible with a multiple-block batch read command (0406) of the MC protocol. Executable commands are ... More Details >>
- No:22726
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Remedy to an error message when performing online change in LCPU
After data is written to the program cache memory (SRAM), it is automatically transferred to the program memory (flash ROM). Therefore, additional online cha... More Details >>
- No:22763
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:50
- Category: MELSEC-L Series
-
Q6BAT. More Details >>
- No:22780
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
A password can be set. - Use the file password 32 function.- Number of characters: 4 to 32 (alphanumeric and special characters, case-sensitive)- Disabled op... More Details >>
- No:22810
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Use of END cover with the branch module and extension module
Use an END cover applicable to the following. - The L6EC whose serial number (first six digits) is "*****2" or later- END cover with ERR terminal (optional i... More Details >>
- No:22815
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Precautions for insertion and removal of SD memory card
Turn off the SD memory card switch and check that the LED indicator is off before insertion or removal of an SD memory card. More Details >>
- No:22818
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
- Ambient temperature: 25+/-5degrees Celsius Full scalex (+/-0.3%) - Ambient temperature: 0 to 55degrees Celsius Full scalex (+/-0.7%) More Details >>
- No:22823
- Release Date:2018/09/03 17:30
- Update:2018/09/27 11:35
- Category: MELSEC-L Series
-
Identifying an SFC program block in execution
Specify a block in the cross reference list and search it. (For block 1, search BL1, for example.) More Details >>
- No:22907
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Copying device comments in GX Works2
Select a device comment in the project view and select "Copy" from the right-click menu. More Details >>
- No:22950
- Release Date:2018/09/03 17:30
- Category: Engineering Software
411-420 of Total 1023